OSHA SearchOSHA records by employer

Park Side Construction, Inc.: OSHA inspections and violations

New York, New York · Poured Concrete Foundation and Structure Contractors · NAICS 238110

7inspections
17citation items
$45,695current penalties
Jan 12, 2016last inspection

Since 2014, OSHA inspectors have visited Park Side Construction, Inc. in New York 7 times.

The most recent inspection opened on Jan 12, 2016, in New York.

In all, OSHA issued 17 citation items: 12 serious, 1 repeat and 4 other-than-serious.

The proposed penalties came to $64,050; today they stand at $45,695, 29% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Park Side Construction, Inc. averages $4,497 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Park Side Construction, Inc.: OSHA citation items per year, 2014 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Park Side Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341187052 OPENED JAN 12, 2016Closed

Unprogrammed other · Complete · Safety · 100 employees at the site · Closed Nov 17, 2017

20 W 40th Street, New York, NY 10018 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Repeat$6,160$4,497Apr 5, 2016Final

Inspection 341093532 OPENED NOV 19, 2015Closed

Referral · Complete · Safety · 55 employees at the site · Closed Nov 20, 2015

116 W 58th St, New York, NY 10019 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340938257 OPENED SEP 23, 2015Closed

Follow-up · Partial · Safety · 30 employees at the site · Closed Oct 2, 2015

9 Orchard Street, New York, NY 10002 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340136100 OPENED DEC 10, 2014Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jan 20, 2016

101 West 28th Street, New York, NY 10001 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$5,390$5,390Apr 24, 2015Final

Inspection 340091396 OPENED OCT 27, 2014Closed

Unprogrammed related · Partial · Safety · 30 employees at the site · Closed Nov 17, 2017

9 Orchard Street, New York, NY 10002 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,900$3,577Apr 24, 2015Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,900$3,577Apr 24, 2015Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,900$3,577Apr 24, 2015Final
Citation 1, item 4
29 CFR 1926.703(b)(1) · Requirements for cast-in-place concrete
Serious$4,900$3,577Apr 24, 2015Final

Inspection 339967093 OPENED SEP 23, 2014Closed

Fatality or catastrophe · Complete · Safety · 8 employees at the site · Closed Mar 13, 2017

326 W 37th Street, New York, NY 10018 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 23, 2014 (fatal): Employee is crushed and killed when section of concrete foun

At approximately 1:30 p.m. on September 23, 2014, an employee was digging with a shovel and pulling wood out from under the foundation wall to prepare for pouring concrete under the wall. Suddenly, the 8,000 pound section of concrete foundation wall tipped over onto the employee. The part of the wall that fell over was a previous concrete repair section that was part of but not securely connected to the rest of the 100 year old building foundation. The employee was crushed and killed. Shoring was not being used and the section that collapsed was the end-corner of the foundation wall and apparently was not tied in at the corner.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Other-than-serious$7,000$7,000Mar 20, 2015Final
Citation 1, item 4a
29 CFR 1926.651(i)(1) · Excavations
Serious$7,000$7,000Mar 20, 2015Final
Citation 1, item 4b
29 CFR 1926.652(a)(1) · Trench protection
Serious$7,000$0Mar 20, 2015Final

Inspection 339603102 OPENED FEB 24, 2014Closed

Complaint · Complete · Safety · 20 employees at the site · Closed Mar 30, 2015

81 Fleet Place, Brooklyn, N.y. 11201, Brooklyn, NY 11201 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(2)(i) · Fall protection in construction
Serious$4,900$3,100May 27, 2014Final
Citation 1, item 1b
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$0$0May 27, 2014Final
Citation 1, item 2a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,500$2,200May 27, 2014Final
Citation 1, item 2b
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$0$0May 27, 2014Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,500$2,200May 27, 2014Final
Citation 2, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 27, 2014Final
Citation 2, item 1b
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0May 27, 2014Final
Citation 2, item 1c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0May 27, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.703 · Requirements for cast-in-place concrete

Other poured concrete foundation and structure contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.