Parker Hannifin Corporation: OSHA inspections and violations
Holt, Michigan · Fluid Power Valve and Hose Fitting Manufacturing · NAICS 332912
15inspections
126citation items
$36,490current penalties
Oct 13, 2025last inspection
OSHA has inspected Parker Hannifin Corporation 15 times in Michigan since 1990.
The latest one began on Oct 13, 2025 after a complaint, in Lakeview.
Those inspections ended with 126 citation items: 41 serious, 16 repeat and 69 other-than-serious.
Penalties were first proposed at $38,940 and now stand at $36,490, 6% lower after settlements or reviews.
comes up most often in these citations: 9 items under 4081.125.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Parker Hannifin Corporation averages $11,200 (1 cited inspection).
Parker Hannifin Corporation also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Michigan · latest 90 days of OSHA records
617employers cited
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Parker Hannifin Corporation and get notified the morning OSHA posts a new citation for it.
OSHA records show Parker Hannifin Corporation at 100 sites in 18 states. Together they've had 324 inspections and $968,799 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 100 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Mason site logged 0 recordable injuries or illnesses among about 79 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Fluid Connectors Mason
Mason · 2025
79
0
0
0.0
2.4
Motion Systems Plymouth
Plymouth · 2025
49
0
0
0.0
1.9
Motion Systems Richland
Richland · 2024
283
1
0
0.4
2.4
Fluid Connectors Lakeview
Lakeview · 2024
171
2
1
1.4
2.7
Motion Systems : Plymouth
Plymouth · 2023
49
0
0
0.0
1.9
Richland site
Richland · 2017
304
7
3
2.2
2.4
Fluid Connectors : Lakeview
Lakeview · 2016
113
2
0
1.6
2.7
Included with any plan: 10 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
29 CFR 1910.110 · Storage and handling of liquefied petroleum gases
29 CFR 1910.110(f)(2)(ii)
(ii) Containers when stored inside shall not be located near exits, stairways, or in areas normally used or intended for the safe exit of people.
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.