OSHA SearchOSHA records by employer

Parkinson Technologies Inc.: OSHA inspections and violations

Woonsocket, Rhode Island · Iron and Steel Mills and Ferroalloy Manufacturing · NAICS 331110

2inspections
7citation items
$5,460current penalties
Mar 24, 2025last inspection

Since 2023, OSHA inspectors have visited Parkinson Technologies Inc. in Rhode Island 2 times.

The most recent inspection opened on Mar 24, 2025 as a planned inspection, in Woonsocket.

In all, OSHA issued 7 citation items: 2 serious and 5 other-than-serious.

The proposed penalties came to $8,666; today they stand at $5,460, 37% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Parkinson Technologies Inc. averages $2,730 across 2 cited inspections.

Parkinson Technologies Inc. also files yearly injury logs with OSHA, summarized below.

Parkinson Technologies Inc.: OSHA citation items per year, 2023 to 2025
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

81employers cited

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Parkinson Technologies Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348128158 OPENED MAR 24, 2025Closed

Planned · Complete · Safety · 53 employees at the site · Closed Jun 27, 2025

100 Goldstein Drive, Woonsocket, RI 02895 · Iron and Steel Mills and Ferroalloy Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(1)(ii)(b) · Overhead and gantry cranes
Other-than-serious$869$608May 30, 2025Final
Citation 1, item 2a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$869$608May 30, 2025Final
Citation 1, item 2b
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Other-than-serious$0$0May 30, 2025Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$869$608May 30, 2025Final

Inspection 346725328 OPENED MAY 24, 2023Closed

Planned · Complete · Safety · 65 employees at the site · Closed Oct 17, 2023

100 Goldstein Drive, Woonsocket, RI 02895 · Iron and Steel Mills and Ferroalloy Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$5,313$3,188Sep 7, 2023Final
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 7, 2023Final
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$746$448Sep 7, 2023Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Woonsocket site logged 1 recordable injury or illness among about 55 workers: 1.7 per 100 full-time workers, against a median of 2.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Parkinson technologies, Inc.
Woonsocket · 2024
55 101.72.3

Included with any plan: 3 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.