OSHA SearchOSHA records by employer

Paulsen Construction LLC: OSHA inspections and violations

Salt Lake City, Utah · Commercial and Institutional Building Construction · NAICS 236220

7inspections
15citation items
$870current penalties
Jul 29, 2024last inspection

OSHA has inspected Paulsen Construction LLC 7 times in Utah since 1973.

The latest one began on Jul 29, 2024 after a complaint, in Salt Lake City.

Those inspections ended with 15 citation items: 1 serious and 14 other-than-serious.

Penalties were first proposed at $1,620 and now stand at $870, 46% lower after settlements or reviews.

[Reserved] comes up most often in these citations: 3 items under 1926.401.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Paulsen Construction LLC averages $750 (1 cited inspection).

The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.

Paulsen Construction LLC: OSHA citation items per year, 1973 to 2024
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Paulsen Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347648396 OPENED JUL 29, 2024Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Aug 8, 2024

210 E 400 S, Salt Lake City, UT 84111 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342328507 OPENED MAY 16, 2017Closed

Referral · Partial · Safety · 30 employees at the site · Closed Apr 26, 2018

Murray City Park 5000 S State St., Murray, UT 84107 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342152410 OPENED FEB 23, 2017Closed

Referral · Partial · Safety · 20 employees at the site · Closed Apr 27, 2017

5350 W 5400 S, Kearns, UT 84118 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$1,500$750Mar 28, 2017Final

Inspection 316931195 OPENED MAY 3, 2013Closed

Planned · Partial · Safety · 19 employees at the site · Closed Sep 2, 2014

10 South Main Street, Ephraim, UT 84627 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 217995935 OPENED OCT 13, 1983Closed

Planned · Complete · Safety · 18 employees at the site · Closed Mar 16, 1984

Physical Education Bldg, Orem, UT 84057 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR CON005006
Other-than-serious$0$0Oct 18, 1983Closed
Citation 1, item 2
29 CFR CON010001
Other-than-serious$0$0Oct 18, 1983Closed
Citation 1, item 3
29 CFR CON01500328
Other-than-serious$0$0Oct 18, 1983Closed
Citation 1, item 4
29 CFR CON030406
Other-than-serious$0$0Oct 18, 1983Closed

Inspection 217916717 OPENED SEP 6, 1973Closed

Planned · Complete · Safety · 30 employees at the site · Closed Mar 10, 1984

Byu Campus, Provo, UT 84601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.401(a)(1) · [Reserved]
Other-than-serious$0$0Sep 13, 1973Closed

Inspection 217918044 OPENED MAR 20, 1973Closed

Planned · Complete · Safety · 9 employees at the site · Closed Mar 10, 1984

4351 South Redwood Road, Salt Lake City, UT 84115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.401(a) · [Reserved]
Other-than-serious$30$30Mar 26, 1973Closed
Citation 1, item 2
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$30$30Mar 26, 1973Closed
Citation 1, item 3
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Mar 26, 1973Closed
Citation 1, item 4
29 CFR 1926.450(b)(12) · Scope, application and definitions applicable to this subpart
Other-than-serious$30$30Mar 26, 1973Closed
Citation 1, item 5
29 CFR 1910.213(c)(1) · Woodworking machinery
Other-than-serious$30$30Mar 26, 1973Closed
Citation 1, item 6
29 CFR 1926.500(e)(1)(iv) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Mar 26, 1973Closed
Citation 1, item 7
29 CFR 1926.401(j)(1) · [Reserved]
Other-than-serious$0$0Mar 26, 1973Closed
Citation 1, item 8
29 CFR 1926.56(a) · Illumination
Other-than-serious$0$0Mar 26, 1973Closed
Citation 1, item 10
29 CFR 1926.150(c)(1) · Fire protection
Other-than-serious$0$0Mar 26, 1973Closed

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Aug 18, 2015 to Aug 17, 2017
Salt Lake City
10$0$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(h)(4)

(4) Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.

29 CFR 1926.150 · Fire protection

29 CFR 1926.401 · [Reserved]

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.56 · Illumination

Other commercial and institutional building construction employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.