OSHA SearchOSHA records by employer

PDQ Construction LLC.: OSHA inspections and violations

Herriman, Utah · Framing Contractors · NAICS 238130

1inspections
5citation items
$8,000current penalties
Jul 20, 2021last inspection

OSHA has inspected PDQ Construction LLC. once in Utah.

The inspection began on Jul 20, 2021 as a planned inspection, in Herriman.

That inspection ended with 5 citation items: 5 repeat.

Penalties were first proposed at $8,000 and still stand at $8,000.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and PDQ Construction LLC. averages $8,000 (1 cited inspection).

PDQ Construction LLC.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

68employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch PDQ Construction LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345427785 OPENED JUL 20, 2021Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jun 30, 2022

Teton Park Dr (6240 W) X Elkridge Way (11865 S) Lot 202, Herriman, UT 84096 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,000$4,000Aug 9, 2021Final
Citation 1, item 2a
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Repeat$4,000$4,000Aug 9, 2021Final
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$0$0Aug 9, 2021Final
Citation 1, item 2c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$0$0Aug 9, 2021Final
Citation 1, item 2d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Repeat$0$0Aug 9, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(v)

(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.