Inspection 349268052 OPENED NOV 5, 2026Open
1610 North Salem Street, Apex, NC 27523 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Apex, North Carolina · Fabricated Structural Metal Manufacturing · NAICS 332312
Peak Steel L.L.C. has 3 OSHA inspections on record in North Carolina, the first in 2016.
OSHA's last visit started on Nov 5, 2026 as a planned inspection, in Apex, and the case has not closed yet.
Across those inspections OSHA issued 4 citation items: 4 serious.
OSHA proposed $5,200 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.147, lockout/tagout (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Peak Steel L.L.C. averages $2,600 over 2 cited inspections in that time.
North Carolina · latest 90 days of OSHA records
234employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Peak Steel L.L.C. and get notified the morning OSHA posts a new citation for it.
Watch this company1610 North Salem Street, Apex, NC 27523 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
1610 N. Salem St, Apex, NC 27523 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $2,000 | $2,000 | Jun 15, 2023 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $0 | $0 | Jun 15, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $2,000 | $2,000 | Jun 15, 2023 | Final |
1610 North Salem Street, Apex, NC 27523 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting |
Serious | $1,200 | $1,200 | Dec 13, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(7)(i)(a)
(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.
29 CFR 1910.212(a)(3)(ii)
(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.