Inspection 349137067 OPENED AUG 27, 2026Open
7133 Germantown, Philadelphia, PA 19119 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Philadelphia, Pennsylvania · Electric Power Distribution · NAICS 221122
Peco Energy Company has 22 OSHA inspections on record in Pennsylvania, the first in 1994.
OSHA's last visit started on Aug 27, 2026 on a referral, in Philadelphia, and the case has not closed yet.
Across those inspections OSHA issued 37 citation items: 29 serious and 8 other-than-serious.
OSHA proposed $101,783 in penalties. After settlements and reviews the total is $83,644, down 18%.
Most often, OSHA cited 1910.146, permit-required confined spaces (15 items).
For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Peco Energy Company averages $12,260 over 2 cited inspections in that time.
6 inspections on this page followed a fatal incident.
Peco Energy Company also files yearly injury logs with OSHA, summarized below.
It reported 5 severe injuries to OSHA since 2015.
Pennsylvania · latest 90 days of OSHA records
274employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Peco Energy Company and get notified the morning OSHA posts a new citation for it.
Watch this company7133 Germantown, Philadelphia, PA 19119 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
520 Markel Rd, Conshohocken, PA 19428 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3901 Conshohocken Ave, Philadelphia, PA 19131 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
905 Tower Rd., Bristol, PA 19007 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Kings Grant Drive And City Avenue, Philadelphia, PA 19131 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.269(e)(7) · Electric power generation, transmission, and distribution |
Serious | $16,550 | $11,585 | Mar 11, 2025 | Final |
680 Ridge Pike, Conshohocken, PA 19428 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2000 Chemical Rd, Plymouth Meeting, PA 19462 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8th & Race, Philadelphia, PA 19106 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
737 Berwood Ln., Bryn Mawr, PA 19010 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on Jun 21, 2017 (fatal): Employee is electrocuted by electric power line
At 5:30 a.m. on June 21, 2017, an employee was installing a bell on a primary line. The line was energized when he handled it. The decedent was not wearing appropriate electrical gloves. The employee touched the line and was electrocuted.
No citations from this inspection.
2704 Cornell Court, Malvern, PA 19355 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.269(c)(3)(ii) · Electric power generation, transmission, and distribution |
Serious | $11,408 | $12,934 | Feb 27, 2017 | Final |
2200 Market Street, Philadelphia, PA 19103 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
191 Ewart Rd, Avondale, PA 19311 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
Incident on May 25, 2011 (fatal): Employee falls from pole, later dies
On May 25, 2011, an employee, a technician was responding to an emergency call. After assessing the damages he contacted the dispatcher and went on to make the location safe. The employee was not sure if the company for which he worked had jurisdiction to work on that pole, and he was told by the dispatcher that the co mpany want one pole in. He leaned a ladder on the 25 ft pole to secure some elec trical wires which had been pulled earlier by a garbage truck. The pole failed t o support the weight of the utility worker who had tied the ladder to the pole, when it broke close to the ground. The employee fell approximately 17 ft. Emerge ncy medical personnel responded and the employee was loaded into a helicopter an d flown to a nearby hospital where he was treated for injuries to his head, arms , and right side of the body. The employee died nine days later. The cause of de ath was multiple blunt force injuries. No maintenance records were found for the privately owned pole which was probably stressed approximately two hours earlie r, when a garbage truck pulled the electrical wires on it. Witnesses stated the force by which the garbage truck pulled the wires, shook the electrical wires vi olently. In addition, the witness reported that an electrical pole on the street , approximately 90 feet away from the downed pole, was observed swaying. A hard hat, gloves and a climbing belt were found at the scene.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.269(a)(2)(i) · Electric power generation, transmission, and distribution |
Serious | $6,300 | $5,000 | Nov 10, 2011 | Final |
| Citation 1, item 1b 29 CFR 1910.269(c)(3) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | Nov 10, 2011 | Final |
| Citation 1, item 1c 29 CFR 1910.269(q)(1)(i) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | Nov 10, 2011 | Final |
2158 Sproul Rd., Broomall, PA 19008 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1075 Susquehanna Road, Abington, PA 19046 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on Jan 30, 2006 (fatal): Employee is electrocuted when struck by falling power line
At approximately 10:55 a.m. on January 30, 2006, Employee #1, a power company li neman, was standing on the ground when he was struck by the energized A-phase of a 13.2-KV primary line that had separated into two lengths. Employee #1 was fat ally electrocuted.
No citations from this inspection.
400 Park Avenue, Warminster, PA 18974 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.180(h)(1)(i) · Crawler locomotive and truck cranes |
Serious | $2,500 | $2,500 | Feb 24, 2005 | Closed |
| Citation 1, item 1b 29 CFR 1910.180(h)(3)(ix) · Crawler locomotive and truck cranes |
Serious | $0 | $0 | Feb 24, 2005 | Closed |
241-243 Chestnut Street, Philadelphia, PA 19106 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2213 Winding Way, Broomall, PA 19008 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
#1 Industrial Highway, Eddystone, PA 19022 · OSHA's record · Phone and website on Google Maps
Incident on Sep 6, 1997 (fatal): Employee killed by water lance
Employee #1 was working inside a confined space. He was cut and killed by a wate r lance. (The original abstract did not describe how the accident occurred.)
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.146(c)(5)(iib) · Permit-required confined spaces |
Serious | $3,150 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 3 29 CFR 1910.146(c)(5)(iic) · Permit-required confined spaces |
Other-than-serious | $2,250 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 4b 29 CFR 1910.146(c)(8)(iii) · Permit-required confined spaces |
Serious | $0 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 5 29 CFR 1910.146(d)(4)(vii) · Permit-required confined spaces |
Serious | $3,150 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 6 29 CFR 1910.146(d)(9) · Permit-required confined spaces |
Serious | $6,300 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 9 29 CFR 1910.146(f)(13) · Permit-required confined spaces |
Serious | $6,300 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 10 29 CFR 1910.146(j)(2) · Permit-required confined spaces |
Serious | $6,300 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 11 29 CFR 1910.146(j)(4) · Permit-required confined spaces |
Serious | $6,300 | $3,000 | Mar 3, 1998 | Final |
| Citation 1, item 14a 29 CFR 1910.146(k)(2)(i) · Permit-required confined spaces |
Serious | $6,300 | $4,000 | Mar 3, 1998 | Final |
| Citation 1, item 14b 29 CFR 1910.146(k)(2)(ii) · Permit-required confined spaces |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 15a 29 CFR 1910.146(k)(3)(i) · Permit-required confined spaces |
Serious | $6,300 | $4,000 | Mar 3, 1998 | Final |
| Citation 1, item 15b 29 CFR 1910.146(k)(3)(ii) · Permit-required confined spaces |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 16a 29 CFR 1910.269(b)(1)(ii) · Electric power generation, transmission, and distribution |
Serious | $1,350 | $4,000 | Mar 3, 1998 | Final |
| Citation 1, item 16d 29 CFR 1910.269(d)(3)(iia)(2) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 16e 29 CFR 1910.269(d)(3)(iid) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 17a 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Other-than-serious | $4,000 | $4,000 | Mar 3, 1998 | Final |
| Citation 1, item 17b 29 CFR 1910.146(e)(6) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 17c 29 CFR 1910.146(f)(4) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Mar 3, 1998 | Final |
#1 Industrial Highway, Eddystone, PA 19022 · OSHA's record · Phone and website on Google Maps
Incident on Sep 6, 1997 (fatal): Employee killed by water lance
Employee #1 was working inside a confined space. He was cut and killed by a wate r lance. (The original abstract did not describe how the accident occurred.)
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response |
Serious | $2,250 | $2,000 | Mar 3, 1998 | Final |
| Citation 1, item 1b 29 CFR 1910.120(q)(6)(iia) · Hazardous waste operations and emergency response |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 1c 29 CFR 1910.120(q)(8)(i) · Hazardous waste operations and emergency response |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 1d 29 CFR 1910.120(q)(6)(va) · Hazardous waste operations and emergency response |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 3a 29 CFR 1910.134(b)(1) · Respiratory protection |
Serious | $1,350 | $2,000 | Mar 3, 1998 | Final |
| Citation 1, item 3b 29 CFR 1910.134(e)(3) · Respiratory protection |
Serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 5a 29 CFR 1910.156(b)(1) · Fire brigades |
Other-than-serious | $4,500 | $2,000 | Mar 3, 1998 | Final |
| Citation 1, item 5b 29 CFR 1910.156(c)(1) · Fire brigades |
Other-than-serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 5c 29 CFR 1910.156(c)(2) · Fire brigades |
Other-than-serious | $0 | $0 | Mar 3, 1998 | Final |
| Citation 1, item 6 29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens |
Serious | $2,250 | $2,000 | Mar 3, 1998 | Final |
| Citation 1, item 7 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,350 | $2,000 | Mar 3, 1998 | Final |
Limerick Generation Station, Longview Rd, Pottstown, PA 19464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $1,625 | $1,625 | Jan 19, 1995 | Closed |
#1 Industrial Highway, Eddystone, PA 19022 · OSHA's record · Phone and website on Google Maps
Incident on Apr 8, 1994 (fatal): Fall - aerial lift failure
A power line worker was in an aerial lift bucket, lowering the boom back into th e truck bed. A cable on the aerial lift had broken. When a second cable broke, t he boom fell freely, causing the employee to fall out of the bucket. The employe e, who was not using fall protection equipment, was killed.
No citations from this inspection.
P.o. Box 2300, Sanatoga, PA 19464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Philadelphia site logged 45 recordable injuries or illnesses among about 3,169 workers: 1.2 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 790 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| PECO Energy Company Philadelphia · 2025 | 3,169 | 45 | 15 | 1.2 | 1.0 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 5 reports on file.
Jan 8, 2025, Philadelphia: Hospitalization · fractures · rib(s), oblique area
An employee was walking across the jobsite when they slipped on black ice and fell to the ground. The employee was hospitalized with three fractured ribs.
Sep 16, 2024, Philadelphia: Hospitalization · electrical burns and electrocution · body systems and other part(s) of body
An employee was preparing to "prove phases" by sending power to another underground section. The employee entered a manhole and contacted an energized conductor via a grounded probe. This caused a flashover event and the employee sustained electrical shock and burns to face.
Jul 19, 2023, Philadelphia: Hospitalization · effects of heat and light, n.e.c. · body systems
An employee was working underground when he began experiencing symptoms of heat exhaustion. The employee was hospitalized for dehydration and heat illness.
Jan 29, 2019, Philadelphia: Hospitalization · fractures · lower leg(s)
An employee fell while exiting the bucket of a bucket truck and suffered a fractured tibia. The employee was hospitalized.
Jul 24, 2018, Philadelphia: Hospitalization · fractures · hip(s)
While reaching for a paper towel dispenser, an employee lost balance and fell to the floor, suffering a broken left hip. The employee was hospitalized.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1030(c)(1)(i)
(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.
29 CFR 1910.120(q)(1)
(1) A laminated, dated card or certificate with photo, denoting limitations and level of protection for which the employee is trained should be issued to those students successfully completing a course.
29 CFR 1910.120(q)(6)(iia)
(A) Knowledge of the basic hazard and risk assessment techniques.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.