OSHA SearchOSHA records by employer

Pedro Ruiz dba Ruiz Masonry: OSHA inspections and violations

Louisville, Kentucky · Masonry Contractors · NAICS 238140

1inspections
3citation items
$3,500current penalties
Apr 15, 2015last inspection

OSHA inspectors have visited Pedro Ruiz dba Ruiz Masonry in Kentucky one time.

It opened on Apr 15, 2015 on a referral, in Louisville.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $10,500; today they stand at $3,500, 67% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pedro Ruiz dba Ruiz Masonry averages $3,500 across 1 cited inspection.

Pedro Ruiz dba Ruiz Masonry: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

191employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Pedro Ruiz dba Ruiz Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317645067 OPENED APR 15, 2015Closed

Referral · Partial · Safety · 10 employees at the site · Closed Apr 5, 2017

13313 Shelbyville Rd., Louisville, KY 40220 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$3,500$1,500May 29, 2015Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,500$500May 29, 2015Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$3,500$1,500May 29, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vi)

(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).

Other masonry contractors employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.