Pendergraft Construction: OSHA inspections and violations

Webb City, Missouri · Framing Contractors · NAICS 238130

2inspections
11citation items
$34,853current penalties
Jan 6, 2023last inspection

Pendergraft Construction has 2 OSHA inspections on record in Missouri, the first in 2019.

OSHA's last visit started on Jan 6, 2023 as a planned inspection, in Joplin.

Across those inspections OSHA issued 11 citation items: 9 serious and 2 repeat.

OSHA proposed $47,589 in penalties. After settlements and reviews the total is $34,853, down 27%.

Most often, OSHA cited 1926.501, fall protection in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pendergraft Construction averages $17,427 over 2 cited inspections in that time.

Pendergraft Construction: OSHA citation items per year, 2019 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Pendergraft Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346424088 OPENED JAN 6, 2023Closed

Planned · Partial · Safety · 9 employees at the site · Closed Sep 3, 2026

1924 East 20th Street, Joplin, MO 64804 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$4,688$4,688Jun 23, 2023Final
Citation 1, item 2b
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Jun 23, 2023Final
Citation 1, item 2c
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$4,688$0Jun 23, 2023Final
Citation 1, item 5
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$4,688$4,688Jun 23, 2023Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$9,375$7,567Jun 23, 2023Final
Citation 2, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$9,375$7,567Jun 23, 2023Final

Inspection 343874327 OPENED MAR 18, 2019Closed

Planned · Partial · Safety · 7 employees at the site · Closed May 31, 2019

South Ellis Street And Fountain Road, Webb City, MO 64870 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,273$1,591May 8, 2019Final
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,273$1,591May 8, 2019Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,978$2,785May 8, 2019Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,978$2,785May 8, 2019Final
Citation 1, item 5
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,273$1,591May 8, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Missouri