OSHA SearchOSHA records by employer

Penn Stucco Systems, Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Masonry Contractors · NAICS 238140

1inspections
5citation items
$119,790current penalties
Nov 3, 2015last inspection

Penn Stucco Systems, Inc. has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Nov 3, 2015 as part of a related case, in Philadelphia.

From that inspection OSHA issued 5 citation items: 1 serious and 4 repeat.

OSHA proposed $119,790 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Penn Stucco Systems, Inc. averages $119,790 over 1 cited inspection in that time.

Penn Stucco Systems, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Penn Stucco Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341330546 OPENED NOV 3, 2015Closed

Unprogrammed related · Complete · Health · 9 employees at the site · Closed Sep 4, 2024

3018 West Thompson Street, Philadelphia, PA 19121 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$5,390$5,390May 2, 2016Final
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$30,800$30,800May 2, 2016Final
Citation 2, item 2
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Repeat$30,800$30,800May 2, 2016Final
Citation 2, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$22,000$22,000May 2, 2016Final
Citation 2, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$30,800$30,800May 2, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.