Since 2015, OSHA inspectors have visited Pennmark Technologies Corporation in Pennsylvania 4 times.
The most recent inspection opened on May 31, 2019 on a referral, in Dallas.
In all, OSHA issued 4 citation items: 1 serious, 2 repeat and 1 other-than-serious.
The proposed penalties came to $88,205; today they stand at $54,500, 38% less.
The rule cited most here is 1910.212 (machine guarding), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Pennmark Technologies Corporation averages $18,167 across 3 cited inspections.
Pennmark Technologies Corporation also files yearly injury logs with OSHA, summarized below.
It reported 4 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Pennsylvania · latest 90 days of OSHA records
285employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Pennmark Technologies Corporation and get notified the morning OSHA posts a new citation for it.
Incident on May 10, 2019: Employee amputates thumb tip when caught in press brake
At 3:30 p.m. on May 10, 2019, an employee was loading and operating a press brake to manufacture brackets. The employee placed a piece of metal (to be bent) onto the die and held onto the piece and as he initiated the press brake cycle by the use of a foot pedal. The employee caught his right thumb tip between the punch and die and incurred an amputation as a result requiring medical treatment. The employee was not hospitalized.
Incident on Feb 8, 2019: Employee's fingertip is amputated on punch press
At 3:00 p.m. on February 8, 2019, an employee was working for a firm that manufactured sheet metal work. He was at an ironworker's punch press station. The narrative did not state whether he had been assigned to that station. He was using the punch press to stamp pieces of metal. He started to talk to a coworker. As he did, he rested his hand near the die of the punch press station. He inadvertently stepped on the punch press's activation foot pedal. The die descended and struck the tip of the index finger on his left hand. The fingertip was amputated. He was hospitalized.
No citations from this inspection.
Inspection 341425759 OPENED APR 26, 2016Closed
Referral · Partial · Safety · 140 employees at the site · Closed Aug 2, 2016
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2017, the Dallas site logged 16 recordable injuries or illnesses among about 166 workers: 10.2 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 14 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Pennmark Technologies Corp
Dallas · 2017
166
16
1
10.2
3.6
Included with any plan: 1 more yearly log from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.
May 10, 2019, Dallas: Amputation · amputations · fingertip(s)
A temporary worker was operating a press brake to bend a 70mm piece of sheet metal. Their right hand was caught in the press when it was actuated resulting in amputation of the thumb tip.
Feb 8, 2019, Dallas: Amputation · amputations · fingertip(s)
An employee was operating a stamping die and crushed his fingers in the machine resulting in amputation of the left index fingertip.
Oct 11, 2017, Dallas: Amputation · amputations · fingertip(s)
On October 11, 2017, at approximately 9:10 PM, an employee was operating a press brake (equipped with laser guard) to bend a metal part when his right index fingertip was pinched and amputated between the part and the machine.
An employee was bending parts on a brake press when their finger entered the point of operation while the machine cycled. The employee sustained a right index finger amputation.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.
Other sheet metal work manufacturing employers in Pennsylvania
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.