Inspection 343024584 OPENED MAR 15, 2018Closed
4520 Hardin Rd, Pope Valley, CA 94567 · Soil Preparation, Planting, and Cultivating · OSHA's record · Phone and website on Google Maps
Incident on Mar 7, 2018: Employee is burned with hot water when pump discharge hose f
At 12:00 p.m. on March 7, 2018, an employee was working for a firm that managed vineyards. He was using a Gorman-Rupp 10-Series Model Number 16A2 (SAE 4/10) self-priming pump to transfer water from a drain tile sump to an irrigation pond. When he checked the sump level to verify that water was being transferred, he noticed that the level was not decreasing. He moved to shut down the pump to see if it had been primed. As he did this, the pump discharge hose coupler blew off the threaded discharge pipe fitting. The employee was sprayed with hot water. He sustained second degree burns on his left chest and left arm. He was hospitalized for approximately forty-eight hours.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 342(A) |
Other-than-serious | $5,000 | $5,000 | Aug 8, 2018 | Final |
| Citation 1, item 2 29 CFR 3328(A)(2) |
Other-than-serious | $200 | $200 | Aug 8, 2018 | Final |