OSHA SearchOSHA records by employer

Performance Contracting Inc: OSHA inspections and violations

Lewiston, Idaho · Drywall and Insulation Contractors · NAICS 238310

4inspections
3citation items
$9,284current penalties
Jul 1, 2021last inspection

Performance Contracting Inc has 4 OSHA inspections on record in Idaho, the first in 1987.

OSHA's last visit started on Jul 1, 2021, in Moscow.

Across those inspections OSHA issued 3 citation items: 3 other-than-serious.

OSHA proposed $9,284 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Performance Contracting Inc averages $9,284 over 1 cited inspection in that time.

Performance Contracting Inc: OSHA citation items per year, 1987 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Performance Contracting Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345397566 OPENED JUL 1, 2021Closed

Unprogrammed other · Partial · Safety · 70 employees at the site · Closed Nov 22, 2021

900 Stadium Dr., Moscow, ID 83843 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$5,803$5,803Sep 3, 2021Final
Citation 1, item 1b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$0$0Sep 3, 2021Final
Citation 1, item 2
29 CFR 1926.34(a) · Means of egress
Other-than-serious$3,481$3,481Sep 3, 2021Final

Inspection 311580351 OPENED JAN 13, 2009Closed

Planned · Partial · Safety · 20 employees at the site · Closed Mar 5, 2009

2003 N. Lincoln Way, Coeur D Alene, ID 83814 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309967081 OPENED DEC 19, 2006Closed

Unprogrammed related · Partial · Safety · 18 employees at the site · Closed Jan 26, 2007

602 Sandpoint Ave, Bldg #7, Sandpoint, ID 83864 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101896249 OPENED JUL 9, 1987Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jul 23, 1987

21st & Thain, Lewiston, ID 83501 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.34 · Means of egress

29 CFR 1926.34(a)

(a) General. In every building or structure exits shall be so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it is occupied. No lock or fastening to prevent free escape from the inside of any building shall be installed except in mental, penal, or corrective institutions where supervisory personnel is continually on duty and effective provisions are made to remove occupants in case of fire or other emergency.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

Other drywall and insulation contractors employers in Idaho

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.