OSHA SearchOSHA records by employer

Perry Electric Inc.: OSHA inspections and violations

Wiscasset, Maine · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
4citation items
$4,437current penalties
Oct 16, 2024last inspection

OSHA has inspected Perry Electric Inc. 2 times in Maine since 2006.

The latest one began on Oct 16, 2024 on a referral, in Sanford.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $6,939 and now stand at $4,437, 36% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Perry Electric Inc. averages $3,387 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Perry Electric Inc.: OSHA citation items per year, 2006 to 2024
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Perry Electric Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347820540 OPENED OCT 16, 2024Closed

Referral · Partial · Safety · 5 employees at the site · Closed Nov 6, 2024

1364 Main Street, Sanford, ME 04073 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,839$3,387Oct 22, 2024Final

Inspection 112517040 OPENED MAR 16, 2006Closed

Planned · Complete · Safety · 3 employees at the site · Closed Apr 6, 2006

Route 1, Wiscasset, ME 04578 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$525Mar 22, 2006Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$600$300Mar 22, 2006Closed
Citation 1, item 3
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$450$225Mar 22, 2006Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 15, 2024, Sanford: Hospitalization · fractures · leg(s) unspecified

An employee was replacing commercial lighting on a ceiling from a scissor lift about 8-9 feet from the floor. He was shocked and fell from the scissor lift to the floor, suffering a broken leg.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.503 · Fall protection training in construction

Other electrical contractors and other wiring installation contractors employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.