OSHA SearchOSHA records by employer

Perry Smith Development, LLC: OSHA inspections and violations

Pigeon Forge, Tennessee · Commercial and Institutional Building Construction · NAICS 236220

3inspections
10citation items
$21,600current penalties
Sep 6, 2023last inspection

Since 2022, OSHA inspectors have visited Perry Smith Development, LLC in Tennessee 3 times.

The most recent inspection opened on Sep 6, 2023 as a planned inspection, in Gatlinburg.

In all, OSHA issued 10 citation items: 6 serious, 3 repeat and 1 other-than-serious.

The penalties, $21,600 in total, stand where OSHA first set them.

The rule cited most here is 1926.1052 (stairways in construction), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Perry Smith Development, LLC averages $7,200 across 3 cited inspections.

Perry Smith Development, LLC: OSHA citation items per year, 2022 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Perry Smith Development, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346957129 OPENED SEP 6, 2023Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 11, 2024

Glades Rd, Gatlinburg, TN 37738 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,000$2,000Nov 9, 2023Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$8,000$8,000Nov 9, 2023Final
Citation 2, item 2a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Repeat$2,400$2,400Nov 9, 2023Final
Citation 2, item 2b
29 CFR 1926.1052(c)(4) · Stairways in construction
Repeat$0$0Nov 9, 2023Final

Inspection 346293046 OPENED OCT 20, 2022Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 25, 2023

2139 New Era Road, Sevierville, TN 37862 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,000$4,000Dec 27, 2022Final
Citation 1, item 2
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$500$500Dec 27, 2022Final
Citation 1, item 3a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$600$600Dec 27, 2022Final
Citation 1, item 3b
29 CFR 1926.1052(c)(4) · Stairways in construction
Serious$0$0Dec 27, 2022Final

Inspection 346074438 OPENED JUL 13, 2022Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Oct 31, 2022

3035 Ridge Top Resort Way, Pigeon Forge, TN 37863 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,000$4,000Oct 3, 2022Final
Citation 2, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$100$100Oct 3, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1052(c)(4)

(4) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members, shall be provided between the top rail of the stairrail system and the stairway steps.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in Tennessee

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.