Inspection 343722567 OPENED JAN 16, 2019Closed
2330 Peyton Rd., Houston, TX 77032 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.28(b)(3)(iv) · Fall protection in general industry |
Serious | $5,304 | $3,182 | Feb 15, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $6,630 | $3,978 | Feb 15, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $6,630 | $3,978 | Feb 15, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $5,304 | $3,182 | Feb 15, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $6,630 | $3,978 | Feb 15, 2019 | Final |
| Citation 1, item 6 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $3,978 | $2,387 | Feb 15, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 15, 2019 | Final |