Inspection 344402896 OPENED OCT 25, 2019Closed
3780 West 104th St., Hialeah, FL 33018 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected PGT Industries Inc./Cgi Windows and Doors Inc. 2 times in Florida since 2018.
The latest one began on Oct 25, 2019 to follow up on an earlier case, in Hialeah.
Those inspections ended with 4 citation items: 3 serious and 1 other-than-serious.
Penalties were first proposed at $28,455 and still stand at $28,455.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and PGT Industries Inc./Cgi Windows and Doors Inc. averages $28,455 (1 cited inspection).
Florida · latest 90 days of OSHA records
316employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch PGT Industries Inc./Cgi Windows and Doors Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company3780 West 104th St., Hialeah, FL 33018 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3780 West 104th St, Hialeah, FL 33018 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(i)(5) · Noise |
Serious | $10,163 | $10,163 | Nov 15, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Serious | $12,195 | $12,195 | Nov 15, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.252(c)(1)(iv) · Welding fire safety |
Serious | $6,097 | $6,097 | Nov 15, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.253(b)(4)(i) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Nov 15, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.252(c)(1)(iv)
(iv) Hazard communication. The employer shall include the potentially hazardous materials employed in fluxes, coatings, coverings, and filler metals, all of which are potentially used in welding and cutting, or are released to the atmosphere during welding and cutting, in the program established to comply with the Hazard Communication Standard (HCS) (§ 1910.1200). The employer shall ensure that each employee has access to labels on containers of such materials and safety data sheets, and is trained in accordance with the provisions of § 1910.1200. Potentially hazardous materials shall include but not be limited to the materials itemized in paragraphs (c)(5) through (c)(12) of this section.
29 CFR 1910.253(b)(4)(i)
(4) Oxygen storage. (i) Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.