OSHA SearchOSHA records by employer

Philadelphia Vill DPW: OSHA inspections and violations

Philadelphia, New York · Highway, Street, and Bridge Construction · NAICS 237310

24inspections
67citation items
$0current penalties
Jul 29, 2022last inspection

Since 1990, OSHA inspectors have visited Philadelphia Vill DPW in New York 24 times.

The most recent inspection opened on Jul 29, 2022 to follow up on an earlier case, in Philadelphia.

In all, OSHA issued 67 citation items: 40 serious and 27 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.1200 (hazard communication), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Philadelphia Vill DPW averages $0 across 2 cited inspections.

Philadelphia Vill DPW: OSHA citation items per year, 1990 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Philadelphia Vill DPW and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346265846 OPENED JUL 29, 2022Closed

Follow-up · Partial · Safety · Local government · 4 employees at the site · Closed Jul 29, 2022

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345962534 OPENED APR 27, 2022Closed

Monitoring · Partial · Safety · Local government · 5 employees at the site · Closed Apr 27, 2022

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345734438 OPENED DEC 6, 2021Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Jul 29, 2022

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Apr 16, 2022Final
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$0$0Apr 16, 2022Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Apr 16, 2022Final
Citation 1, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Apr 16, 2022Final
Citation 1, item 5
29 CFR 1910.242(a) · Hand and power tools
Serious$0$0Apr 16, 2022Final
Citation 1, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Apr 16, 2022Final

Inspection 343275186 OPENED JUL 3, 2018Closed

Follow-up · Partial · Health · Local government · 5 employees at the site · Closed Jul 5, 2018

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342827052 OPENED DEC 11, 2017Closed

Planned · Complete · Health · Local government · 5 employees at the site · Closed May 7, 2018

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 12 NYCRR PART 800.6(H)
Serious$0$0Jan 24, 2018Final
Citation 1, item 2
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Jan 24, 2018Final
Citation 1, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Jan 24, 2018Final
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jan 24, 2018Final
Citation 1, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Jan 24, 2018Final
Citation 1, item 6
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Jan 24, 2018Final
Citation 1, item 7
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jan 24, 2018Final
Citation 2, item 1
29 CFR 12 NYCRR PART 801.32(A)(2)
Other-than-serious$0$0Jan 24, 2018Final
Citation 2, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jan 24, 2018Final

Inspection 313564403 OPENED JUN 8, 2010Closed

Follow-up · Partial · Safety · Local government · 5 employees at the site · Closed Jun 9, 2010

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313563025 OPENED MAY 5, 2010Closed

Referral · Partial · Health · Local government · 5 employees at the site · Closed May 20, 2010

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313563942 OPENED APR 1, 2010Closed

Monitoring · Partial · Safety · Local government · 5 employees at the site · Closed Apr 2, 2010

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

16 older inspections

Inspection 313563256 OPENED JAN 26, 2010Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Jun 9, 2010

56 Main St, Philadelphia, NY 13673 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$0$0Feb 8, 2010Closed
Citation 1, item 2
29 CFR 1910.23(d)(1)(i) · Guarding floor and wall openings and holes
Serious$0$0Feb 8, 2010Closed
Citation 1, item 3
29 CFR 1910.24(c) · Fixed industrial stairs
Serious$0$0Feb 8, 2010Closed
Citation 1, item 4
29 CFR 1910.24(h) · Fixed industrial stairs
Serious$0$0Feb 8, 2010Closed
Citation 1, item 5
29 CFR 1910.36(d)(1) · Exit route design
Serious$0$0Feb 8, 2010Closed
Citation 1, item 6
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Feb 8, 2010Closed
Citation 1, item 9
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Feb 8, 2010Closed
Citation 1, item 10
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$0$0Feb 8, 2010Closed
Citation 1, item 11
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Feb 8, 2010Closed
Citation 1, item 12
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Feb 8, 2010Closed
Citation 1, item 13
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Feb 8, 2010Closed
Citation 1, item 14
29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods
Serious$0$0Feb 8, 2010Closed
Citation 1, item 15
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Feb 8, 2010Closed
Citation 1, item 16
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$0$0Feb 8, 2010Closed
Citation 2, item 1
29 CFR 8000006 E01 I
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 2
29 CFR 8000006 F03
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 3
29 CFR 8000006 H01
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 4
29 CFR 1910.38(b) · Emergency action plans
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 5
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 6
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Feb 8, 2010Closed

Inspection 304836984 OPENED MAY 2, 2002Closed

Follow-up · Partial · Safety · Local government · 4 employees at the site · Closed May 2, 2002

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304836992 OPENED MAY 2, 2002Closed

Follow-up · Complete · Safety · Local government · 3 employees at the site · Closed May 2, 2002

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304836539 OPENED FEB 7, 2002Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed May 13, 2002

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304836547 OPENED FEB 7, 2002Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed May 2, 2002

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Feb 22, 2002Closed

Inspection 304836554 OPENED FEB 7, 2002Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed May 14, 2002

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(b)(6) · Flammable liquids
Serious$0$0Feb 26, 2002Closed
Citation 1, item 2
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$0$0Feb 26, 2002Closed
Citation 1, item 3 Serious$0$0Feb 26, 2002Closed
Citation 1, item 4
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Feb 26, 2002Closed
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Feb 26, 2002Closed
Citation 2, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Feb 26, 2002Closed

Inspection 115869927 OPENED OCT 29, 1996Closed

Follow-up · Partial · Safety · Local government · 30 employees at the site · Closed Oct 29, 1996

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 115869893 OPENED JAN 16, 1996Closed

Unprogrammed related · Partial · Safety · Local government · 30 employees at the site · Closed Oct 29, 1996

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response
Serious$0$0Jan 30, 1996Closed

Inspection 108452335 OPENED SEP 11, 1991Closed

Follow-up · Partial · Health · Local government · 5 employees at the site · Closed Dec 9, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(g)(1)(i) · Flammable liquids
Other-than-serious$0$0Oct 9, 1991Closed
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 9, 1991Closed
Citation 1, item 3
29 CFR 1910.1200(f)(4)(ii) · Hazard communication
Other-than-serious$0$0Oct 9, 1991Closed

Inspection 108452293 OPENED AUG 28, 1991Closed

Follow-up · Partial · Health · Local government · 6 employees at the site · Closed Aug 28, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108449356 OPENED JUL 15, 1991Closed

Follow-up · Partial · Safety · Local government · 5 employees at the site · Closed Jul 15, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104955885 OPENED APR 5, 1991Closed

Monitoring · Partial · Safety · Local government · 5 employees at the site · Closed Apr 5, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104955919 OPENED MAR 19, 1991Closed

Planned · Partial · Health · Local government · 6 employees at the site · Closed Aug 28, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(f)(1) · Welding fire safety
Other-than-serious$0$0Mar 21, 1991Closed
Citation 1, item 2
29 CFR 8010006 A
Other-than-serious$0$0Mar 21, 1991Closed

Inspection 104953971 OPENED NOV 5, 1990Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Jan 23, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104940721 OPENED OCT 25, 1990Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Jul 15, 1991

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Serious$0$0Nov 8, 1990Closed
Citation 1, item 2
29 CFR 1910.23(e)(2) · Guarding floor and wall openings and holes
Serious$0$0Nov 8, 1990Closed
Citation 1, item 3
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Serious$0$0Nov 8, 1990Closed
Citation 1, item 4
29 CFR 1910.106(g)(5)(iii) · Flammable liquids
Serious$0$0Nov 8, 1990Closed
Citation 1, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Nov 9, 1990Closed
Citation 1, item 6
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$0$0Nov 9, 1990Closed
Citation 1, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Nov 9, 1990Closed
Citation 2, item 1 Other-than-serious$0$0Nov 9, 1990Closed
Citation 2, item 2
29 CFR 1910.36(b)(8) · Exit route design
Other-than-serious$0$0Nov 9, 1990Closed
Citation 2, item 3
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0Nov 9, 1990Closed
Citation 2, item 4
29 CFR 1910.37(g)(1) · Exit routes
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 5
29 CFR 1910.106(b)(2)(vib) · Flammable liquids
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 6
29 CFR 1910.176(c) · Material storage and aisles
Other-than-serious$0$0Nov 9, 1990Closed
Citation 2, item 7
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 8
29 CFR 1910.252(a)(2)(iid) · Welding fire safety
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 9
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 10
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 11
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Nov 8, 1990Closed
Citation 2, item 12
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Nov 8, 1990Closed

Inspection 104940713 OPENED OCT 24, 1990Closed

Planned · Complete · Safety · Local government · 9 employees at the site · Closed Oct 24, 1990

56 Main St, Philadelphia, NY 13673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(b)(2)(vib)

(vi) Vent piping for aboveground tanks. (a) Vent piping shall be constructed in accordance with paragraph (c) of this section.

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(g)(1)(i)

(g) Service stations—(1) Storage and handling—(i) General provisions. (a) Liquids shall be stored in approved closed containers not exceeding 60 gallons capacity, in tanks located underground, in tanks in special enclosures as described in paragraph (g)(i) of this section, or in aboveground tanks as provided for in paragraphs (g)(4)(ii), (b), (c) and (d) of this section.

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.184 · Slings

29 CFR 1910.20

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other highway, street, and bridge construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.