Inspection 344440839 OPENED NOV 4, 2019Closed
4411 #d Kikowaena St., Lihue, HI 96766 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pics LLC has 3 OSHA inspections on record in Hawaii, the first in 2012.
OSHA's last visit started on Nov 4, 2019 as a planned inspection, in Lihue.
Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
OSHA proposed $4,812 in penalties. After settlements and reviews the total is $3,052, down 37%.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pics LLC averages $2,640 over 1 cited inspection in that time.
Want to know if OSHA cites Pics LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company4411 #d Kikowaena St., Lihue, HI 96766 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Malino Nei Pl, Koloa, HI 96756 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(k)(1) · Excavations |
Serious | $2,200 | $1,320 | Jun 4, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $2,200 | $1,320 | Jun 4, 2015 | Final |
4411 D Kikowaena St, Lihue, HI 96766 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $412 | $412 | Jul 31, 2012 | Closed |
| Citation 1, item 1b 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Jul 31, 2012 | Closed |
| Citation 2, item 1 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 31, 2012 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.157(e)(3)
(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.
29 CFR 1910.304(g)(5)
(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.