Inspection 345081004 OPENED DEC 18, 2020Closed
8511-a Norcross Rd, Colfax, NC 27235 · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Colfax, North Carolina · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · NAICS 333923
Since 1999, OSHA inspectors have visited Piedmont Hoist and Crane, Inc. in North Carolina 6 times.
The most recent inspection opened on Dec 18, 2020 to follow up on an earlier case, in Colfax.
In all, OSHA issued 40 citation items: 15 serious and 25 other-than-serious.
The proposed penalties came to $17,050; today they stand at $11,380, 33% less.
The rule cited most here is 1910.1200 (hazard communication), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Piedmont Hoist and Crane, Inc. averages $10,530 across 1 cited inspection.
North Carolina · latest 90 days of OSHA records
228employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Piedmont Hoist and Crane, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company8511-a Norcross Rd, Colfax, NC 27235 · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8511-a Norcross Rd, Colfax, NC 27235 · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8511-a Norcross Rd, Colfax, NC 27235 · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.133(a)(1) · Eye and face protection |
Serious | $2,000 | $1,300 | Aug 20, 2020 | Final |
| Citation 1, item 1b 29 CFR 1910.133(a)(3) · Eye and face protection |
Serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 1, item 1c 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.179(b)(8) · Overhead and gantry cranes |
Serious | $2,000 | $1,300 | Aug 20, 2020 | Final |
| Citation 1, item 3a 29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes |
Serious | $2,800 | $1,820 | Aug 20, 2020 | Final |
| Citation 1, item 3b 29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes |
Serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 1, item 4a 29 CFR 1910.184(i)(1) · Slings |
Serious | $2,800 | $1,820 | Aug 20, 2020 | Final |
| Citation 1, item 4b 29 CFR 1910.184(i)(9)(iii) · Slings |
Serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 1, item 5 29 CFR 1910.242(b) · Hand and power tools |
Serious | $1,200 | $780 | Aug 20, 2020 | Final |
| Citation 1, item 6 29 CFR 1910.252(c)(2)(i) · Welding fire safety |
Serious | $2,800 | $1,820 | Aug 20, 2020 | Final |
| Citation 1, item 7 29 CFR 1910.1026(d)(1) · Hexavalent chromium |
Serious | $2,000 | $1,300 | Aug 20, 2020 | Final |
| Citation 1, item 8a 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $600 | $390 | Aug 20, 2020 | Final |
| Citation 1, item 8b 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 2, item 2 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 20, 2020 | Final |
| Citation 2, item 3 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Aug 20, 2020 | Final |
8511-a Norcross Rd., Colfax, NC 27235 · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $750 | $750 | Jun 18, 2014 | Closed |
| Citation 1, item 1b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 2 29 CFR 1910.106(d)(5)(i) · Flammable liquids |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 3 29 CFR 1910.184(i)(1) · Slings |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 4 29 CFR 1910.253(e)(6)(ii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 5 29 CFR 1910.255(c)(2) · Resistance welding |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 6 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
| Citation 2, item 7 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 18, 2014 | Closed |
8511-a Norcross Road, Colfax, NC 27235 · Overhead Traveling Crane, Hoist, and Monorail System Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.37(q)(2) · Exit routes |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 1b 29 CFR 1910.37(q)(5) · Exit routes |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 2 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 3a 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 3b 29 CFR 1910.157(c)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 4 29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 5 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 6a 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
| Citation 1, item 6b 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Other-than-serious | $0 | $0 | Jul 26, 2006 | Closed |
8511 Norcross Road, Colfax, NC 27235 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $100 | $100 | Jul 21, 1999 | Closed |
| Citation 1, item 1b 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $0 | $0 | Jul 21, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.38(a)(1) · Emergency action plans |
Other-than-serious | $0 | $0 | Jul 21, 1999 | Closed |
| Citation 2, item 2 29 CFR 1910.304(f)(7)(iic) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 21, 1999 | Closed |
| Citation 2, item 3 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 21, 1999 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 21, 1999 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.1026(d)(1)
(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.
29 CFR 1910.106(d)(5)(i)
(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.