OSHA SearchOSHA records by employer

Pilkin Electric, LLC: OSHA inspections and violations

Clifton, New Jersey · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
2citation items
$4,695current penalties
Mar 25, 2021last inspection

Pilkin Electric, LLC has 2 OSHA inspections on record in New Jersey, the first in 2017.

OSHA's last visit started on Mar 25, 2021 as a planned inspection, in Hackensack.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,021 in penalties. After settlements and reviews the total is $4,695, down 33%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pilkin Electric, LLC averages $2,348 over 2 cited inspections in that time.

Pilkin Electric, LLC: OSHA citation items per year, 2017 to 2021
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

272employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Pilkin Electric, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345220834 OPENED MAR 25, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 7, 2021

80 S River St, Hackensack, NJ 07601 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,218$2,414Sep 20, 2021Final

Inspection 342236577 OPENED APR 10, 2017Closed

Referral · Partial · Health · 3 employees at the site · Closed Aug 29, 2017

20 Bridewell Place, Clifton, NJ 07014 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 10, 2017: Electrician repairing light fixture is electrocuted

At 11:30 a.m. on April 10, 2017, Employee #1, an electrician employed by an electrical services company, was working from a Genie scissor lift extended more than 10 feet above the ground. He was inspecting high bay light fixtures to determine which one was flickering. Employee #1 attempted to disconnect the relock safety connector which serviced the light fixture and thereby de-energize the ballast. He was squeezing the safety connector when it became stuck and began to spark and arch. A fire ensued. Employee #1 sustained an electric shock that entered at his left hand's index finger. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for an electric shock.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$3,803$2,282Jul 5, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

Other electrical contractors and other wiring installation contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.