OSHA SearchOSHA records by employer

Pioneer Molded Products Inc: OSHA inspections and violations

Grand Rapids, Michigan · All Other Plastics Product Manufacturing · NAICS 326199

5inspections
15citation items
$6,700current penalties
Feb 10, 2020last inspection

Pioneer Molded Products Inc has 5 OSHA inspections on record in Michigan, the first in 2011.

OSHA's last visit started on Feb 10, 2020 after a complaint, in Grand Rapids.

Across those inspections OSHA issued 15 citation items: 12 serious and 3 other-than-serious.

OSHA proposed $14,100 in penalties. After settlements and reviews the total is $6,700, down 52%.

Most often, OSHA cited 1910.147, lockout/tagout (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Pioneer Molded Products Inc averages $3,500 over 1 cited inspection in that time.

Pioneer Molded Products Inc: OSHA citation items per year, 2011 to 2020
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

621employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Pioneer Molded Products Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344592217 OPENED FEB 10, 2020Closed

Complaint · Partial · Safety · 60 employees at the site · Closed Aug 5, 2020

5505 52nd St Se, Grand Rapids, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.16211(1)
Serious$3,500$1,750Apr 17, 2020Final
Citation 1, item 1b
29 CFR 408.16227(2)
Serious$0$0Apr 17, 2020Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,500$1,750Apr 17, 2020Final
Citation 2, item 1
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Apr 17, 2020Final

Inspection 315392670 OPENED AUG 14, 2012Closed

Planned · No inspection · Safety · Closed Aug 14, 2012

5505 52nd St Se, Grand Rapids, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315392514 OPENED JUN 12, 2012Closed

Unprogrammed related · Partial · Safety · 35 employees at the site · Closed Nov 27, 2012

5505 52nd St Se, Grand Rapids, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$800$400Jul 30, 2012Closed
Citation 1, item 1b Serious$0$0Jul 30, 2012Closed
Citation 1, item 1c Serious$0$0Jul 30, 2012Closed
Citation 1, item 1d Serious$0$0Jul 30, 2012Closed
Citation 1, item 2
29 CFR 1910.147(c)(2)(iii) · Lockout/tagout
Serious$1,400$700Jul 30, 2012Closed
Citation 1, item 3a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,400$700Jul 30, 2012Closed
Citation 1, item 3b
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$0$0Jul 30, 2012Closed
Citation 2, item 1 Other-than-serious$0$0Jul 30, 2012Closed

Inspection 315392506 OPENED JUN 11, 2012Closed

Follow-up · Partial · Safety · 35 employees at the site · Closed Mar 12, 2014

5505 52nd St Se, Grand Rapids, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312062532 OPENED JUL 27, 2011Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Mar 12, 2014

5505 52nd St Se, Grand Rapids, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,000$400Sep 15, 2011Closed
Citation 1, item 2 Serious$2,500$1,000Sep 15, 2011Closed
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 15, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(2)(iii)

(iii) After January 2, 1990, whenever replacement or major repair, renovation or modification of a machine or equipment is performed, and whenever new machines or equipment are installed, energy isolating devices for such machine or equipment shall be designed to accept a lockout device.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 3254.7201

29 CFR 4081.3308

29 CFR 4081.3309

29 CFR 4081.3313

29 CFR 4081.3392

29 CFR 4081.3394

29 CFR 4081.34

Other all other plastics product manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.