OSHA SearchOSHA records by employer

Pirhl Contractors, LLC: OSHA inspections and violations

Princess Anne, Maryland · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

2inspections
3citation items
$0current penalties
Oct 20, 2017last inspection

OSHA has inspected Pirhl Contractors, LLC 2 times in Maryland since 2012.

The latest one began on Oct 20, 2017 as a planned inspection, in Frederick.

Those inspections ended with 3 citation items: 3 other-than-serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Pirhl Contractors, LLC averages $0 (1 cited inspection).

Pirhl Contractors, LLC: OSHA citation items per year, 2012 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Pirhl Contractors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342723202 OPENED OCT 20, 2017Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 5, 2018

520 N. Market St., Frederick, MD 21701 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Jan 4, 2018Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Jan 4, 2018Final

Inspection 316247279 OPENED MAR 14, 2012Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 4, 2012

30500 Riggin Street, Princess Anne, MD 21853 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Other-than-serious$0$0Apr 10, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

Other new multifamily housing construction (except for-sale builders) employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.