OSHA SearchOSHA records by employer

Pittsfield Waste Water Department: OSHA inspections and violations

Pittsfield, Massachusetts · Sewage Treatment Facilities · NAICS 221320

1inspections
4citation items
$0current penalties
Jan 23, 2026last inspection

OSHA has inspected Pittsfield Waste Water Department once in Massachusetts.

The inspection began on Jan 23, 2026 after a complaint, in Pittsfield.

That inspection ended with 4 citation items: 4 serious.

None of the citations carried a penalty.

Permit-required confined spaces comes up most often in these citations: 2 items under 1910.146.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Pittsfield Waste Water Department averages $0 (1 cited inspection).

Pittsfield Waste Water Department: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

264employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Pittsfield Waste Water Department and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348711367 OPENED JAN 23, 2026Closed

Complaint · Partial · Health · Local government · 25 employees at the site · Closed Jun 29, 2026

901 Holmes Rd., Pittsfield, MA 01201 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(3)(v) · Fall protection in general industry
Serious$0$0Feb 19, 2026Final
Citation 1, item 2
29 CFR 1910.146(d)(3) · Permit-required confined spaces
Serious$0$0Feb 19, 2026Final
Citation 1, item 3
29 CFR 1910.146(j)(2) · Permit-required confined spaces
Serious$0$0Feb 19, 2026Final
Citation 1, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Feb 19, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(d)(3)

(3) Develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, the following:

29 CFR 1910.146(j)(2)

(2) Verifies, by checking that the appropriate entries have been made on the permit, that all tests specified by the permit have been conducted and that all procedures and equipment specified by the permit are in place before endorsing the permit and allowing entry to begin;

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.28 · Fall protection in general industry

Other sewage treatment facilities employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.