OSHA SearchOSHA records by employer

Polyflo, Inc.: OSHA inspections and violations

Saint Clair, Pennsylvania · All Other Plastics Product Manufacturing · NAICS 326199

4inspections
8citation items
$5,850current penalties
Dec 1, 2015last inspection

Polyflo, Inc. has 4 OSHA inspections on record in Pennsylvania, the first in 2006.

OSHA's last visit started on Dec 1, 2015 as a planned inspection, in Saint Clair.

Across those inspections OSHA issued 8 citation items: 5 serious, 1 repeat and 2 other-than-serious.

OSHA proposed $10,225 in penalties. After settlements and reviews the total is $5,850, down 43%.

Most often, OSHA cited 1910.37, exit routes (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Polyflo, Inc. averages $0 over 1 cited inspection in that time.

Polyflo, Inc. also files yearly injury logs with OSHA, summarized below.

Polyflo, Inc.: OSHA citation items per year, 2006 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Polyflo, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341088367 OPENED DEC 1, 2015Closed

Planned · Partial · Safety · 25 employees at the site · Closed Feb 22, 2016

2 Tension Way, Saint Clair, PA 17970 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(4) · Exit routes
Other-than-serious$0$0Dec 15, 2015Final

Inspection 339514341 OPENED DEC 10, 2013Closed

Planned · Partial · Safety · 27 employees at the site · Closed Mar 7, 2014

2 Tension Way, Saint Clair, PA 17970 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$2,100$0Jan 23, 2014Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$2,800$2,500Jan 23, 2014Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$2,100$2,000Jan 23, 2014Final

Inspection 310233168 OPENED MAY 7, 2008Closed

Planned · Partial · Safety · 30 employees at the site · Closed Sep 16, 2008

2 Tension Way Street, St Clair, PA 17970 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$3,000$1,200May 29, 2008Closed

Inspection 307919902 OPENED MAY 3, 2006Closed

Planned · Partial · Safety · 25 employees at the site · Closed Aug 1, 2006

Po Box 309, 2 Tension Way, Saint Clair, PA 17970 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$125$85May 26, 2006Closed
Citation 1, item 2a
29 CFR 1910.147(c)(8) · Lockout/tagout
Serious$100$65May 26, 2006Closed
Citation 1, item 2b
29 CFR 1910.147(f)(2)(i) · Lockout/tagout
Serious$0$0May 26, 2006Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Saint Clair site logged 1 recordable injury or illness among about 26 workers: 3.9 per 100 full-time workers, against a median of 1.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
PolyFlo, Inc.
Saint Clair · 2025
26 103.91.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(8)

(8) Energy isolation. Lockout or tagout shall be performed only by the authorized employees who are performing the servicing or maintenance.

29 CFR 1910.147(f)(2)(i)

(2) Check the work area to ensure that all employees have been safely positioned or removed from the area.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other all other plastics product manufacturing employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.