Ponce Brothers Construction, Inc.: OSHA inspections and violations

Plant City, Florida · Masonry Contractors · NAICS 238140

1inspections
3citation items
$2,040current penalties
Jan 22, 2015last inspection

OSHA inspectors have visited Ponce Brothers Construction, Inc. in Florida one time.

It opened on Jan 22, 2015 as a planned inspection, in Plant City.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $2,040 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ponce Brothers Construction, Inc. averages $2,040 across 1 cited inspection.

Ponce Brothers Construction, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Ponce Brothers Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340200054 OPENED JAN 22, 2015Closed

Planned · Complete · Safety · 10 employees at the site · Closed May 16, 2017

2370 Walden Woods Dr., Plant City, FL 33565 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,020$1,020Feb 24, 2015Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,020$1,020Feb 24, 2015Final
Citation 1, item 2b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Feb 24, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.