OSHA SearchOSHA records by employer

Pond View Construction, LLC: OSHA inspections and violations

Collegeville, Pennsylvania · Framing Contractors · NAICS 238130

1inspections
4citation items
$2,880current penalties
Mar 24, 2015last inspection

OSHA inspectors have visited Pond View Construction, LLC in Pennsylvania one time.

It opened on Mar 24, 2015 on a referral, in Collegeville.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $5,760; today they stand at $2,880, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pond View Construction, LLC averages $2,880 across 1 cited inspection.

Pond View Construction, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Pond View Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340486851 OPENED MAR 24, 2015Closed

Referral · Partial · Safety · 8 employees at the site · Closed Mar 7, 2016

White Springs At Providence, Collegeville, PA 19426 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,600$800Mar 30, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,400Mar 30, 2015Final
Citation 1, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$1,360$680Mar 30, 2015Final
Citation 2, item 1
29 CFR 1926.1402(b) · Ground conditions
Other-than-serious$0$0Mar 30, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1402 · Ground conditions

29 CFR 1926.1402(b)

(b) The equipment must not be assembled or used unless ground conditions are firm, drained, and graded to a sufficient extent so that, in conjunction (if necessary) with the use of supporting materials, the equipment manufacturer's specifications for adequate support and degree of level of the equipment are met. The requirement for the ground to be drained does not apply to marshes/wetlands.

29 CFR 1926.501 · Fall protection in construction