OSHA SearchOSHA records by employer

Pontillo and Sons, Inc.: OSHA inspections and violations

Brockport, New York · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

2inspections
3citation items
$1,020current penalties
Oct 22, 2021last inspection

Pontillo and Sons, Inc. has 2 OSHA inspections on record in New York, the first in 2015.

OSHA's last visit started on Oct 22, 2021 as a planned inspection, in Webster.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $2,932 in penalties. After settlements and reviews the total is $1,020, down 65%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pontillo and Sons, Inc. averages $510 over 2 cited inspections in that time.

Pontillo and Sons, Inc.: OSHA citation items per year, 2015 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Pontillo and Sons, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345610893 OPENED OCT 22, 2021Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 9, 2023

1838 Empire Boulevard, Webster, NY 14580 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,492$300Dec 20, 2021Final

Inspection 340682608 OPENED JUN 3, 2015Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Feb 23, 2016

668 Fourth Section Road, Brockport, NY 14420 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,440$720Aug 19, 2015Final
Citation 1, item 1b
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$0$0Aug 19, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

Other other foundation, structure, and building exterior contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.