OSHA SearchOSHA records by employer

Popular Design Mill & Cabinet Inc.: OSHA inspections and violations

West Valley, Utah · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
5citation items
$2,875current penalties
Sep 21, 2018last inspection

Popular Design Mill & Cabinet Inc. has one OSHA inspection on record in Utah.

OSHA opened it on Sep 21, 2018 as a planned inspection, in West Valley.

From that inspection OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

OSHA proposed $4,750 in penalties. After settlements and reviews the total is $2,875, down 39%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Popular Design Mill & Cabinet Inc. averages $2,875 over 1 cited inspection in that time.

Popular Design Mill & Cabinet Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

74employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Popular Design Mill & Cabinet Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343481842 OPENED SEP 21, 2018Closed

Planned · Partial · Safety · 42 employees at the site · Closed Nov 16, 2018

2821 Parkway Bvld, West Valley, UT 84119 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(r)(4) · Woodworking machinery
Serious$2,500$1,250Oct 17, 2018Final
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,250$625Oct 17, 2018Final
Citation 1, item 2b
29 CFR 1910.303(e)(1) · Electrical equipment, general requirements
Serious$0$0Oct 17, 2018Final
Citation 2, item 1
29 CFR UAC R614-1-5.C.1
Other-than-serious$500$500Oct 17, 2018Final
Citation 2, item 2
29 CFR UAC R614-1-5.C.2
Other-than-serious$500$500Oct 17, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(r)(4)

(4) The mention of specific machines in paragraphs (a) thru (q) and this paragraph (r) of this section, inclusive, is not intended to exclude other woodworking machines from the requirement that suitable guards and exhaust hoods be provided to reduce to a minimum the hazard due to the point of operation of such machines.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(e)(1)

(e) Marking—(1) Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment:

Other wood kitchen cabinet and countertop manufacturing employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.