Inspection 344383047 OPENED OCT 16, 2019Closed
120 Lower Cherry St, Potsdam, NY 13676 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2009, OSHA inspectors have visited Potsdam Vill DPW in New York 5 times.
The most recent inspection opened on Oct 16, 2019 to follow up on an earlier case, in Potsdam.
In all, OSHA issued 12 citation items: 9 serious and 3 other-than-serious.
No penalty came with these citations.
The rule cited most here is 1926.1153 (silica dust in construction), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Potsdam Vill DPW averages $0 across 2 cited inspections.
New York · latest 90 days of OSHA records
362employers cited
21 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Potsdam Vill DPW and get notified the morning OSHA posts a new citation for it.
Watch this company120 Lower Cherry St, Potsdam, NY 13676 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
120 Lower Cherry St, Potsdam, NY 13676 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(5) · Ladders in general industry |
Serious | $0 | $0 | Aug 21, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $0 | $0 | Aug 21, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Aug 21, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection |
Serious | $0 | $0 | Aug 21, 2019 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 801.29(A) |
Other-than-serious | $0 | $0 | Aug 21, 2019 | Final |
| Citation 2, item 2 29 CFR 12 NYCRR PART 801.29(B) |
Other-than-serious | $0 | $0 | Aug 21, 2019 | Final |
120 Lower Cherry St, Potsdam, NY 13676 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Serious | $0 | $0 | Nov 13, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.146(g)(1) · Permit-required confined spaces |
Serious | $0 | $0 | Nov 13, 2019 | Final |
| Citation 1, item 3 29 CFR 1926.1153(g)(1) · Silica dust in construction |
Serious | $0 | $0 | Nov 13, 2019 | Final |
| Citation 1, item 4 29 CFR 1926.1153(i)(1) · Silica dust in construction |
Serious | $0 | $0 | Nov 13, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 13, 2019 | Final |
120 Lower Cherry Street, Potsdam, NY 13676 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
120 Lower Cherry Street, Potsdam, NY 13676 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(2) · General requirements |
Serious | $0 | $0 | Dec 21, 2009 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(ii)
(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).
29 CFR 1910.146(c)(4)
(4) If the employer decides that its employees will enter permit spaces, the employer shall develop and implement a written permit space program that complies with this section. The written program shall be available for inspection by employees and their authorized representatives.
29 CFR 1910.146(g)(1)
(g) Training. (1) The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.