Inspection 345052369 OPENED NOV 2, 2020Closed
Edif. Coliseum Tower Suite 101 Alterial B 576, San Juan, PR 00918 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Nov 2, 2020: Employee falls from height of approximately 16 feet and incu
At 9:30 a.m. on November 2, 2020, an employee was installing a "transfer switch" mount at a height of approximately 16 feet when the intermediate guardrail at station #3 detached, causing the employee to fall. The employee sustained multiple fractures to the face, legs, ribs, and teeth, as well as damage to discs and swelling in the face, which resulted in temporary vision loss. The employee was hospitalized to treat of the injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.22(d)(1) · Walking-working surfaces |
Serious | $1,500 | $1,275 | Mar 24, 2021 | Final |
| Citation 1, item 1b 29 CFR 1910.22(d)(2) · Walking-working surfaces |
Serious | $0 | $0 | Mar 24, 2021 | Final |
| Citation 1, item 2 29 CFR 1910.29(b)(1) · Fall protection systems in general industry |
Serious | $1,500 | $1,275 | Mar 24, 2021 | Final |
| Citation 1, item 3 29 CFR 1910.30(a)(2) · Training requirements |
Serious | $1,500 | $1,275 | Mar 24, 2021 | Final |