Power D.G. Construction, LLC: OSHA inspections and violations

Montebello, New York · Roofing Contractors · NAICS 238160

1inspections
6citation items
$5,000current penalties
Feb 20, 2024last inspection

Power D.G. Construction, LLC has one OSHA inspection on record in New York.

OSHA opened it on Feb 20, 2024 as a planned inspection, in Montebello, and the case has not closed yet.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $12,444 in penalties. After settlements and reviews the total is $5,000, down 60%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Power D.G. Construction, LLC averages $5,000 over 1 cited inspection in that time.

Power D.G. Construction, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

358employers cited

59 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Power D.G. Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347302218 OPENED FEB 20, 2024Open

Planned · Complete · Safety · 3 employees at the site · Open

34 N. Airmont Rd., Montebello, NY 10901 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$3,457$0May 8, 2024Final
Citation 1, item 2a
29 CFR 1926.405(a)(2)(ii)(c) · Job-site wiring
Serious$2,074$0May 8, 2024Final
Citation 1, item 2b
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$0$0May 8, 2024Final
Citation 1, item 3a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,839$3,470May 8, 2024Final
Citation 1, item 3b
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$0$0May 8, 2024Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,074$1,530May 8, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(c)

(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.