OSHA SearchOSHA records by employer

Power Electric LLC: OSHA inspections and violations

Orlando, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
21citation items
$15,815current penalties
Oct 28, 2020last inspection

OSHA has inspected Power Electric LLC 4 times in Florida since 1984.

The latest one began on Oct 28, 2020 on a referral, in Wesley Chapel.

Those inspections ended with 21 citation items: 17 serious, 2 repeat and 2 other-than-serious.

Penalties were first proposed at $25,292 and now stand at $15,815, 37% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 5 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Power Electric LLC averages $9,715 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Power Electric LLC: OSHA citation items per year, 1984 to 2020
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Power Electric LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345001788 OPENED OCT 28, 2020Closed

Referral · Partial · Safety · 9 employees at the site · Closed Mar 29, 2022

5745 Dayflower Blvd, Wesley Chapel, Wesley Chapel, FL 33544 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$4,048$2,429Dec 23, 2020Final
Citation 1, item 2
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$4,048$2,429Dec 23, 2020Final
Citation 1, item 3
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$4,048$2,429Dec 23, 2020Final
Citation 1, item 4
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,048$2,429Dec 23, 2020Final

Inspection 106204514 OPENED AUG 21, 1990Closed

Follow-up · Partial · Safety · 130 employees at the site · Closed Aug 24, 1990

Orlando International Airport, Orlando, FL 32822 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 18077974 OPENED APR 4, 1990Closed

Unprogrammed related · Complete · Safety · 130 employees at the site · Closed Sep 10, 1990

Orlando International Airport, Orlando, FL 32822 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(g)(8) · Hazard communication
Serious$600$400Jul 31, 1990Closed
Citation 1, item 2
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$600$400Jul 31, 1990Closed
Citation 1, item 3
29 CFR 1926.404(b)(2)(ii) · Ground-fault protection on job sites
Serious$900$600Jul 31, 1990Closed
Citation 1, item 4
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$600$400Jul 31, 1990Closed
Citation 1, item 5
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$800$500Jul 31, 1990Closed
Citation 1, item 6
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$200$150Jul 31, 1990Closed
Citation 1, item 7
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$600$400Jul 31, 1990Closed
Citation 1, item 8
29 CFR 1926.405(j)(2)(ii) · Job-site wiring
Serious$200$150Jul 31, 1990Closed
Citation 1, item 9
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$600$400Jul 31, 1990Closed
Citation 1, item 10
29 CFR 1926.451(e)(3) · Scaffolds, general requirements
Serious$400$300Jul 31, 1990Closed
Citation 1, item 11
29 CFR 1926.451(e)(4) · Scaffolds, general requirements
Serious$400$300Jul 31, 1990Closed
Citation 1, item 12 Serious$700$400Jul 31, 1990Closed
Citation 1, item 13 Serious$500$300Jul 31, 1990Closed
Citation 2, item 1
29 CFR 1926.450(a)(2) · Scope, application and definitions applicable to this subpart
Repeat$400$300Jul 31, 1990Closed
Citation 2, item 2
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Repeat$1,600$1,100Jul 31, 1990Closed
Citation 3, item 1
29 CFR 1926.59(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jul 31, 1990Closed
Citation 3, item 2
29 CFR 1926.59(f)(5) · Hazard communication
Other-than-serious$0$0Jul 31, 1990Closed

Inspection 240382 OPENED MAR 26, 1984Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 27, 1984

Fis Facility Orlando Airport, Orlando, FL 32805 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 22, 2020, Wesley Chapel: Hospitalization · electrocutions, electric shocks · body systems

An electrician was working in a junction box. He turned to walk out and his shoulder hit the bar inside of the electrical panel box. He was electrocuted and hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.556

29 CFR 1926.59 · Hazard communication

29 CFR 1926.95 · Criteria for personal protective equipment

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.