OSHA SearchOSHA records by employer

Power Service - a Dnow Company: OSHA inspections and violations

Casper, Wyoming · Industrial Machinery and Equipment Merchant Wholesalers · NAICS 423830

1inspections
3citation items
$17,632current penalties
Jan 7, 2025last inspection

Power Service - a Dnow Company has one OSHA inspection on record in Wyoming.

OSHA opened it on Jan 7, 2025 after a complaint, in Casper.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $17,632 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (2 items).

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,427. Power Service - a Dnow Company averages $17,632 over 1 cited inspection in that time.

Power Service - a Dnow Company: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Power Service - a Dnow Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347962359 OPENED JAN 7, 2025Closed

Complaint · Partial · Safety · 47 employees at the site · Closed Mar 31, 2025

5625 Chapman Place, Casper, WY 82604 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 27-11-105 (B)(VI)(A)
Serious$8,816$8,816Feb 7, 2025Final
Citation 1, item 2a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$8,816$8,816Feb 7, 2025Final
Citation 1, item 2b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Feb 7, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

Other industrial machinery and equipment merchant wholesalers employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.