OSHA SearchOSHA records by employer

Power Systems Electric Corporation: OSHA inspections and violations

Manassas, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
7citation items
$27,093current penalties
Jul 6, 2022last inspection

OSHA has inspected Power Systems Electric Corporation 2 times in Virginia since 2003.

The latest one began on Jul 6, 2022 as a planned inspection, in Arlington.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $27,243 and now stand at $27,093, 1% lower after settlements or reviews.

Safeguards for personnel protection comes up most often in these citations: 3 items under 1910.335.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Power Systems Electric Corporation averages $26,868 (1 cited inspection).

Power Systems Electric Corporation: OSHA citation items per year, 2003 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Power Systems Electric Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346063035 OPENED JUL 6, 2022Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 28, 2022

1101 South Arlington Ridge Road, Arlington, VA 22202 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$13,434$13,434Oct 3, 2022Final
Citation 1, item 1b
29 CFR 1910.333(b)(2)(iv)(b) · Working near live electrical parts
Serious$0$0Oct 3, 2022Final
Citation 1, item 1c
29 CFR 1910.333(b)(2) · Working near live electrical parts
Serious$0$0Oct 3, 2022Final
Citation 1, item 2a
29 CFR 1910.335(a)(2)(ii) · Safeguards for personnel protection
Serious$13,434$13,434Oct 3, 2022Final
Citation 1, item 2b
29 CFR 1910.335(a)(1)(v) · Safeguards for personnel protection
Serious$0$0Oct 3, 2022Final
Citation 1, item 2c
29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection
Serious$0$0Oct 3, 2022Final

Inspection 306823683 OPENED DEC 29, 2003Closed

Planned · Partial · Safety · 1 employee at the site · Closed Feb 11, 2004

8700 Centreville Road, Manassas, VA 20109 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$375$225Jan 21, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.333(b)(2)

(2) The procedures also incorporate the requirements of paragraphs (b)(2)(iii)(D) and (b)(2)(iv)(B) of this section.

29 CFR 1910.333(b)(2)(iv)(b)

(B) A qualified person shall use test equipment to test the circuit elements and electrical parts of equipment to which employees will be exposed and shall verify that the circuit elements and equipment parts are deenergized. The test shall also determine if any energized condition exists as a result of inadvertently induced voltage or unrelated voltage backfeed even though specific parts of the circuit have been deenergized and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be checked for proper operation immediately before and immediately after this test.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1926.453 · Aerial lifts

Other electrical contractors and other wiring installation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.