OSHA SearchOSHA records by employer

Powerscreen USA dba Terex Simplicity USA LLC: OSHA inspections and violations

Durand, Michigan · Conveyor and Conveying Equipment Manufacturing · NAICS 333922

1inspections
4citation items
$1,400current penalties
Jan 10, 2020last inspection

Powerscreen USA dba Terex Simplicity USA LLC has one OSHA inspection on record in Michigan.

OSHA opened it on Jan 10, 2020 as a planned inspection, in Durand.

From that inspection OSHA issued 4 citation items: 1 serious and 3 other-than-serious.

OSHA proposed $2,800 in penalties. After settlements and reviews the total is $1,400, down 50%.

Most often, OSHA cited 1910.334, using electrical equipment (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Powerscreen USA dba Terex Simplicity USA LLC averages $1,400 over 1 cited inspection in that time.

Powerscreen USA dba Terex Simplicity USA LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

641employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Powerscreen USA dba Terex Simplicity USA LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344550132 OPENED JAN 10, 2020Closed

Planned · Complete · Safety · 110 employees at the site · Closed Feb 24, 2020

212 S Oak St, Durand, MI 48429 · Conveyor and Conveying Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(7)
Serious$2,800$1,400Jan 24, 2020Final
Citation 2, item 1
29 CFR 408.10685(3)
Other-than-serious$0$0Jan 24, 2020Final
Citation 2, item 2a
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Jan 24, 2020Final
Citation 2, item 2b
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Other-than-serious$0$0Jan 24, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

29 CFR 1910.334(a)(3)(ii)

(ii) Attachment plugs and receptacles may not be connected or altered in a manner which would prevent proper continuity of the equipment grounding conductor at the point where plugs are attached to receptacles. Additionally, these devices may not be altered to allow the grounding pole of a plug to be inserted into slots intended for connection to the current-carrying conductors.