Precision Electric and Lighting: OSHA inspections and violations

Binghamton, New York · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
12citation items
$5,880current penalties
Mar 25, 2015last inspection

Precision Electric and Lighting has 2 OSHA inspections on record in New York, the first in 2014.

OSHA's last visit started on Mar 25, 2015 as a planned inspection, in Newark.

Across those inspections OSHA issued 12 citation items: 12 serious.

OSHA proposed $8,400 in penalties. After settlements and reviews the total is $5,880, down 30%.

Most often, OSHA cited 1926.405, job-site wiring (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Precision Electric and Lighting averages $5,880 over 1 cited inspection in that time.

Precision Electric and Lighting: OSHA citation items per year, 2014 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Precision Electric and Lighting and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340493741 OPENED MAR 25, 2015Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 21, 2015

Rite Aid, 101 South Main Street, Newark, NY 14513 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.34(c) · Means of egress
Serious$1,200$840Apr 22, 2015Final
Citation 1, item 2a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,400$1,680Apr 22, 2015Final
Citation 1, item 2b
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Serious$0$0Apr 22, 2015Final
Citation 1, item 2c
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0Apr 22, 2015Final
Citation 1, item 2d
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$0$0Apr 22, 2015Final
Citation 1, item 3a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,400$1,680Apr 22, 2015Final
Citation 1, item 3b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Apr 22, 2015Final
Citation 1, item 3c
29 CFR 1926.405(g)(1)(iii) · Job-site wiring
Serious$0$0Apr 22, 2015Final
Citation 1, item 3d Serious$0$0Apr 22, 2015Final
Citation 1, item 4a
29 CFR 1926.405(e)(1) · Job-site wiring
Serious$2,400$1,680Apr 22, 2015Final
Citation 1, item 4b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Apr 22, 2015Final
Citation 1, item 4c
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Apr 22, 2015Final

Inspection 339585168 OPENED FEB 12, 2014Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 14, 2014

Anytime Fitness, 1257 Upper Front Street, Binghamton, NY 13905 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.34 · Means of egress

29 CFR 1926.34(c)

(c) Maintenance and workmanship. Means of egress shall be continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction