Precision Fire Protection, Incorporated: OSHA inspections and violations

Reading, Pennsylvania · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
5citation items
$5,456current penalties
Oct 24, 2018last inspection

OSHA has inspected Precision Fire Protection, Incorporated 2 times in Pennsylvania since 2005.

The latest one began on Oct 24, 2018, in York.

Those inspections ended with 5 citation items: 5 serious.

Penalties were first proposed at $7,462 and now stand at $5,456, 27% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 2 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Precision Fire Protection, Incorporated averages $4,546 (1 cited inspection).

Precision Fire Protection, Incorporated: OSHA citation items per year, 2005 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

287employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Precision Fire Protection, Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343567186 OPENED OCT 24, 2018Closed

Unprogrammed other · Partial · Safety · 17 employees at the site · Closed Feb 22, 2019

770 Stoverstown Road, York, PA 17408 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.302(a)(1) · Power-operated hand tools
Serious$2,273$1,705Jan 30, 2019Final
Citation 1, item 2a
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$3,789$2,842Jan 30, 2019Final
Citation 1, item 2b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jan 30, 2019Final

Inspection 308471481 OPENED APR 28, 2005Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 7, 2005

1700 North 11th Street, Reading, PA 19604 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$700$455May 27, 2005Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iic) · Job-site wiring
Serious$700$455May 27, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.302 · Power-operated hand tools

29 CFR 1926.302(a)(1)

(a) Electric power-operated tools. (1) Electric power operated tools shall either be of the approved double-insulated type or grounded in accordance with subpart K of this part.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iic)

(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.

29 CFR 1926.416 · Electrical safety in construction

Other plumbing, heating, and air-conditioning contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.