Precision Metal Products, Inc. has 5 OSHA inspections on record in Connecticut, the first in 1988.
OSHA's last visit started on Jul 24, 2017 on a referral, in Milford.
Across those inspections OSHA issued 36 citation items: 20 serious and 16 other-than-serious.
OSHA proposed $47,426 in penalties. After settlements and reviews the total is $34,900, down 26%.
Most often, OSHA cited 1910.1200, hazard communication (6 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Precision Metal Products, Inc. averages $18,000 over 1 cited inspection in that time.
Precision Metal Products, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Inspection 342490901 OPENED JUL 24, 2017Closed
Referral · Partial · Safety · 140 employees at the site · Closed Aug 27, 2019
307 Pepes Farm Road, Milford, CT 06460 · Surgical and Medical Instrument Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jul 24, 2017: Employee is operating press machine and crushes hand
At 7:15 a.m. on July 24, 2017, an employee was operating #27 press. The employee was either inserting or removing a premium tool assembly jaw from the press when press was turned on and caught the employee's fingers and hand with the die or ram. The employee suffered crushing injuries and amputated a portion of their hand. No identification was made within the report as to the full extent of the employee's injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1a |
Serious | $11,408 | $8,000 | Sep 5, 2017 | Final |
| Citation 1, item 1b |
Serious | $0 | $0 | Sep 5, 2017 | Final |
| Citation 1, item 2 |
Serious | $6,519 | $4,500 | Sep 5, 2017 | Final |
| Citation 1, item 3 |
Serious | $6,519 | $4,500 | Sep 5, 2017 | Final |
| Citation 2, item 1 |
Other-than-serious | $1,630 | $1,000 | Sep 5, 2017 | Final |
| Citation 2, item 2 |
Other-than-serious | $0 | $0 | Sep 5, 2017 | Final |
Incident on Sep 19, 1996: Employee's finger amputated in power press
At approximately 2:30 a.m. on September 19, 1996, Employee #1 was operating a Mi nster mechanical power press when the chain drive broke, causing the press to op erate in a continuous mode. Employee #1 was reaching into the point of operation to remove a part when the machine cycled and partially amputated a finger. The press did not have an anti-repeat feature installed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $1,925 | $960 | Dec 11, 1996 | Closed |
| Citation 1, item 2 |
Serious | $1,925 | $960 | Dec 11, 1996 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Milford site logged 1 recordable injury or illness among about 85 workers: 1.5 per 100 full-time workers, against a median of 1.1 for its industry.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jul 24, 2017, Milford: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee was removing and/or inserting a point stake from/into an active air press when the machine's ram smashed and amputated fingers from both of her hands.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.