OSHA SearchOSHA records by employer

Precision Pipe & Vessel, LLC: OSHA inspections and violations

Denver, Colorado · Fabricated Structural Metal Manufacturing · NAICS 332312

4inspections
16citation items
$6,540current penalties
Jan 7, 2015last inspection

OSHA has inspected Precision Pipe & Vessel, LLC 4 times in Colorado since 2010.

The latest one began on Jan 7, 2015 after a complaint, in Commerce City.

Those inspections ended with 16 citation items: 8 serious and 8 other-than-serious.

Penalties were first proposed at $10,500 and now stand at $6,540, 38% lower after settlements or reviews.

Hexavalent chromium comes up most often in these citations: 11 items under 1910.1026.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Precision Pipe & Vessel, LLC averages $1,680 (1 cited inspection).

Precision Pipe & Vessel, LLC: OSHA citation items per year, 2010 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

130employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Precision Pipe & Vessel, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340165281 OPENED JAN 7, 2015Closed

Complaint · Partial · Health · 25 employees at the site · Closed Apr 16, 2015

6471 E. 49th Ave, Commerce City, CO 80022 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$2,400$1,680Mar 11, 2015Final

Inspection 314662396 OPENED FEB 3, 2011Closed

Follow-up · Partial · Health · 7 employees at the site · Closed Jul 7, 2011

6535 N Washington, Denver, CO 80229 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jun 21, 2011Closed
Citation 1, item 1b
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Jun 21, 2011Closed

Inspection 313416836 OPENED FEB 24, 2010Closed

Planned · No inspection · Safety · 9 employees at the site · Closed Mar 1, 2010

6535 N Washington, Denver, CO 80229 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313416133 OPENED FEB 2, 2010Closed

Complaint · Partial · Health · 9 employees at the site · Closed Mar 28, 2012

6535 N Washington, Denver, CO 80229 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$450$270Apr 5, 2010Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$600$360Apr 5, 2010Closed
Citation 1, item 3a
29 CFR 1910.1026(c) · Hexavalent chromium
Serious$1,500$900Apr 5, 2010Closed
Citation 1, item 3b
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$0$0Apr 5, 2010Closed
Citation 1, item 3c
29 CFR 1910.1026(g)(1) · Hexavalent chromium
Serious$0$0Apr 5, 2010Closed
Citation 1, item 3d
29 CFR 1910.1026(g)(2) · Hexavalent chromium
Serious$0$0Apr 5, 2010Closed
Citation 1, item 4
29 CFR 1910.1026(e)(1) · Hexavalent chromium
Other-than-serious$1,050$630Apr 5, 2010Closed
Citation 1, item 5
29 CFR 1910.1026(h)(2)(i) · Hexavalent chromium
Other-than-serious$1,050$630Apr 5, 2010Closed
Citation 1, item 6a
29 CFR 1910.1026(j)(2)(i) · Hexavalent chromium
Serious$450$270Apr 5, 2010Closed
Citation 1, item 6b
29 CFR 1910.1026(j)(3)(i) · Hexavalent chromium
Other-than-serious$0$0Apr 5, 2010Closed
Citation 1, item 7a
29 CFR 1910.1026(k)(1)(ia) · Hexavalent chromium
Serious$1,500$900Apr 5, 2010Closed
Citation 1, item 8a
29 CFR 1910.1026(l)(2)(i) · Hexavalent chromium
Other-than-serious$1,500$900Apr 5, 2010Closed
Citation 1, item 8b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Apr 5, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (5 µgm/m 3), calculated as an 8-hour time-weighted average (TWA).

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1026(e)(1)

(e) Regulated areas—(1) Establishment. The employer shall establish a regulated area wherever an employee's exposure to airborne concentrations of chromium (VI) is, or can reasonably be expected to be, in excess of the PEL.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

Other fabricated structural metal manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.