Inspection 344310586 OPENED SEP 13, 2019Closed
6615 Topper Parkway, San Antonio, TX 78233 · Rolled Steel Shape Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
San Antonio, Texas · Rolled Steel Shape Manufacturing · NAICS 331221
Precision Strand and Rebar has 2 OSHA inspections on record in Texas, the first in 2019.
OSHA's last visit started on Sep 13, 2019 on a referral, in San Antonio.
Across those inspections OSHA issued 4 citation items: 4 serious.
OSHA proposed $8,335 in penalties. After settlements and reviews the total is $3,250, down 61%.
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Precision Strand and Rebar averages $3,250 over 1 cited inspection in that time.
Texas · latest 90 days of OSHA records
391employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Precision Strand and Rebar and get notified the morning OSHA posts a new citation for it.
Watch this company6615 Topper Parkway, San Antonio, TX 78233 · Rolled Steel Shape Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6615 Topper Parkway, San Antonio, TX 78233 · Rolled Steel Shape Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $3,031 | $1,500 | Aug 30, 2019 | Final |
| Citation 1, item 2a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $3,031 | $1,250 | Aug 30, 2019 | Final |
| Citation 1, item 2b 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Aug 30, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.305(j)(2)(vii) · Electrical wiring methods |
Serious | $2,273 | $500 | Aug 30, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(1)
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
29 CFR 1910.212(a)(1)
(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.
29 CFR 1910.219(f)(3)
(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.