OSHA SearchOSHA records by employer

Premier Drywall: OSHA inspections and violations

Costa Mesa, California · Commercial and Institutional Building Construction · NAICS 236220

6inspections
7citation items
$2,435current penalties
Jun 7, 2017last inspection

Premier Drywall has 6 OSHA inspections on record in California, the first in 1987.

OSHA's last visit started on Jun 7, 2017 as a planned inspection, in Vandenberg Afb.

Across those inspections OSHA issued 7 citation items: 3 serious and 4 other-than-serious.

OSHA proposed $2,435 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.28, personal protective equipment (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Premier Drywall averages $0 over 1 cited inspection in that time.

Premier Drywall: OSHA citation items per year, 1987 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Premier Drywall again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342408853 OPENED JUN 7, 2017Closed

Planned · Complete · Safety · 9 employees at the site · Closed Oct 27, 2017

Building 7000 Vandenberg Afb, Vandenberg Afb, CA 93437 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Sep 25, 2017Final

Inspection 109350447 OPENED SEP 2, 2004Closed

Planned · Partial · Safety · 80 employees at the site · Closed Sep 2, 2004

1 University Circle, Monterey B, CA 93943 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109338483 OPENED NOV 14, 2000Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Jan 30, 2001

Aeromedical Services Clinic, Edwards Afb, CA 93523 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109508705 OPENED MAR 27, 1997Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 26, 1997

Chemical Test Labratory, Utah Avenue, Vandenburg Afb, CA 93437 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$1,500$1,500May 5, 1997Closed

Inspection 119916625 OPENED MAY 12, 1994Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 19, 1998

2121 W. Vineyard, Templeton, CA 93465 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1509 C
Other-than-serious$85$85May 27, 1994Closed
Citation 1, item 2
29 CFR 1509 A
Other-than-serious$150$150May 27, 1994Closed

Inspection 100959667 OPENED AUG 26, 1987Closed

Unprogrammed related · Complete · Safety · 25 employees at the site · Closed Feb 16, 1988

2855 Pinecreek Dr., Costa Mesa, CA 92676 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$420$420Oct 8, 1987Closed
Citation 1, item 2
29 CFR 1926.28(a) · Personal protective equipment
Serious$280$280Oct 8, 1987Closed
Citation 2, item 1
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$0$0Oct 8, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.28(a)

(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

Other commercial and institutional building construction employers in California

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.