OSHA SearchOSHA records by employer

Premier Water & Energy Technology, LLC.: OSHA inspections and violations

Pensacola, Florida · Other Commercial and Service Industry Machinery Manufacturing · NAICS 333318

1inspections
3citation items
$9,931current penalties
Dec 23, 2024last inspection

OSHA inspectors have visited Premier Water & Energy Technology, LLC. in Florida one time.

It opened on Dec 23, 2024 on a referral, in Pensacola.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $16,552; today they stand at $9,931, 40% less.

The rule cited most here is 1910.147 (lockout/tagout), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Premier Water & Energy Technology, LLC. averages $9,931 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Premier Water & Energy Technology, LLC.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

311employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Premier Water & Energy Technology, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347952400 OPENED DEC 23, 2024Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jun 23, 2025

640 Roberts Avenue Building 511, Pensacola, FL 32511 · Other Commercial and Service Industry Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$8,276$4,966May 14, 2025Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$8,276$4,966May 14, 2025Final
Citation 1, item 2c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0May 14, 2025Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 18, 2024, Pensacola: Hospitalization · avulsions, enucleations without bone loss · scalp

An employee was entering a cooling tower when their hair was pulled into a fan motor that was 5 feet off the ground, resulting in the separation of their scalp from their skull.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(1)

(c) General requirements. (1) The employer shall evaluate the workplace to determine if any spaces are permit- required confined spaces.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

Other other commercial and service industry machinery manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.