OSHA SearchOSHA records by employer

Premium Electric, LLC: OSHA inspections and violations

Rosedale, Maryland · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
7citation items
$1,275current penalties
Oct 28, 2022last inspection

Since 2011, OSHA inspectors have visited Premium Electric, LLC in Maryland 4 times.

The most recent inspection opened on Oct 28, 2022 as a planned inspection, in Glen Burnie.

In all, OSHA issued 7 citation items: 3 serious and 4 other-than-serious.

The penalties, $1,275 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Premium Electric, LLC averages $425 across 3 cited inspections.

Premium Electric, LLC: OSHA citation items per year, 2011 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

187employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Premium Electric, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346312630 OPENED OCT 28, 2022Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 16, 2023

7908 Ritchie Highway, Glen Burnie, MD 21061 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Other-than-serious$0$0Jan 6, 2023Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Jan 6, 2023Final

Inspection 346029911 OPENED JUN 17, 2022Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 23, 2022

8478 Ocean Gateway, Easton, MD 21601 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$1,050Aug 1, 2022Final
Citation 1, item 1b
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$0$0Aug 1, 2022Final

Inspection 342774866 OPENED NOV 16, 2017Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 16, 2018

8711 Ft. Smallwood Rd., Pasadena, MD 21122 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$225$225Jan 23, 2018Final

Inspection 315439653 OPENED MAR 11, 2011Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Jun 1, 2011

1501 62nd Street, Rosedale, MD 21237 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 50405 B01
Other-than-serious$0$0Apr 20, 2011Closed
Citation 1, item 2
29 CFR 50406 A01
Other-than-serious$0$0Apr 20, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other electrical contractors and other wiring installation contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.