OSHA SearchOSHA records by employer

Premium Velocity Auto, LLC.: OSHA inspections and violations

Waterloo, Iowa · General Automotive Repair · NAICS 811111

2inspections
13citation items
$40,982current penalties
Nov 14, 2025last inspection

Premium Velocity Auto, LLC. has 2 OSHA inspections on record in Iowa, the first in 2024.

OSHA's last visit started on Nov 14, 2025 after a complaint, in Des Moines.

Across those inspections OSHA issued 13 citation items: 13 serious.

OSHA proposed $81,965 in penalties. After settlements and reviews the total is $40,982, down 50%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (5 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Premium Velocity Auto, LLC. averages $20,491 over 2 cited inspections in that time.

Premium Velocity Auto, LLC.: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

66employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Premium Velocity Auto, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348594714 OPENED NOV 14, 2025Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Jun 5, 2026

3609 Merle Hay Road, Des Moines, IA 50310 · Automotive Oil Change and Lubrication Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 88.4 - CODE OF IOWA (2021)
Serious$10,641$5,320May 4, 2026Final
Citation 1, item 2a
29 CFR 1910.22(c) · Walking-working surfaces
Serious$10,641$5,320May 4, 2026Final
Citation 1, item 2b
29 CFR 1910.22(d)(1) · Walking-working surfaces
Serious$0$0May 4, 2026Final
Citation 1, item 3a
29 CFR 1910.37(a)(3) · Exit routes
Serious$14,895$7,448May 4, 2026Final
Citation 1, item 3b
29 CFR 1910.37(b)(4) · Exit routes
Serious$0$0May 4, 2026Final
Citation 1, item 4
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$14,895$7,448May 4, 2026Final
Citation 1, item 5a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$12,768$6,384May 4, 2026Final
Citation 1, item 5b
29 CFR 1910.303(b)(7) · Electrical equipment, general requirements
Serious$0$0May 4, 2026Final
Citation 1, item 5c
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Serious$0$0May 4, 2026Final
Citation 1, item 5d
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$0$0May 4, 2026Final
Citation 1, item 5e
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0May 4, 2026Final
Citation 1, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$12,768$6,384May 4, 2026Final

Inspection 347916728 OPENED DEC 5, 2024Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Feb 24, 2025

1423 E San Marnan Dr, Waterloo, IA 50702 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$5,357$2,678Feb 3, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.22(c)

(c) Access and egress. The employer must provide, and ensure each employee uses, a safe means of access and egress to and from walking-working surfaces.

29 CFR 1910.22(d)(1)

(1) Walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition;

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other general automotive repair employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.