Inspection 347301251 OPENED FEB 20, 2024Closed
5252 Highbanks Rd Ste 350, Springfield, OR 97478 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Springfield, Oregon · General Warehousing and Storage · NAICS 493110
Prep Ninjas LLC has 3 OSHA inspections on record in Oregon, the first in 2022.
OSHA's last visit started on Feb 20, 2024 to follow up on an earlier case, in Springfield.
Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.
OSHA proposed $100 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).
For context, across all transportation and warehousing employers the median penalty per cited inspection since 2015 is $3,555. Prep Ninjas LLC averages $100 over 1 cited inspection in that time.
Want to know if OSHA cites Prep Ninjas LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company5252 Highbanks Rd Ste 350, Springfield, OR 97478 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5252 Highbanks Rd Ste 350, Springfield, OR 97478 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements |
Serious | $100 | $100 | Jan 25, 2024 | Final |
| Citation 2, item 2 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 25, 2024 | Final |
| Citation 2, item 3 29 CFR OAR 437-001-0765(11)-3 |
Other-than-serious | $0 | $0 | Jan 25, 2024 | Final |
3804 Kathryn Ave #c, Springfield, OR 97478 · Packing and Crating · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
29 CFR 1910.303(g)(1)(i)(a)
(A) The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.