OSHA SearchOSHA records by employer

Presa Construction, LLC: OSHA inspections and violations

Dallas, Texas · Residential Remodelers · NAICS 236118

1inspections
3citation items
$5,800current penalties
Jul 3, 2024last inspection

OSHA inspectors have visited Presa Construction, LLC in Texas one time.

It opened on Jul 3, 2024 after a fatality or catastrophe, in Dallas.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $9,678; today they stand at $5,800, 40% less.

The rule cited most here is 1926.416 (electrical safety in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Presa Construction, LLC averages $5,800 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Presa Construction, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Presa Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347603482 OPENED JUL 3, 2024Closed

Fatality or catastrophe · Partial · Safety · 4 employees at the site · Closed Feb 13, 2026

3653 Timberglen Road, Dallas, TX 75287 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Incident on Jul 3, 2024 (fatal): Employee is electrocuted when making contact with overhead p

At 9:45 a.m. on July 3, 2024, an employee was assisting a coworker in taking down a 44-foot aluminum extension ladder. During the process, the employees lost control of the ladder, which contacted an overhead power line. The employee sustained fatal injuries due to electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,839$2,900Dec 31, 2024Final
Citation 1, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Dec 31, 2024Final
Citation 1, item 2
29 CFR 1926.1053(b)(12) · Ladders in construction
Serious$4,839$2,900Dec 31, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(12)

(12) Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in § 1926.955(b) and (c) of this part.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

Other residential remodelers employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.