Tulsa, Oklahoma · Plate Work Manufacturing · NAICS 332313
13inspections
11citation items
$3,458current penalties
Aug 2, 2016last inspection
OSHA has inspected Prescor, Inc. 13 times in Oklahoma since 1981.
The latest one began on Aug 2, 2016 as a planned inspection, in Tulsa.
Those inspections ended with 11 citation items: 5 serious and 6 other-than-serious.
Penalties were first proposed at $4,920 and now stand at $3,458, 30% lower after settlements or reviews.
Noise comes up most often in these citations: 2 items under 1910.95.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Prescor, Inc. averages $1,908 (1 cited inspection).
Prescor, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Want to know if OSHA cites Prescor, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Tulsa site logged 10 recordable injuries or illnesses among about 50 workers: 33.7 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 5 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Prescor Inc.
Tulsa · 2023
50
10
2
33.7
3.6
Prescor, LLC
Tulsa · 2022
41
4
0
9.2
3.6
Severe injury reports
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
An employee was taking the plug out of a press. The forks of a forklift had been placed under the plug so it could rest on them when it was unbolted. The employee was unbolting the plug when the forks slipped. The plug fell and crushed the employee's right hand and wrist.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
29 CFR 1910.147(d)(4)(i)
(4) Lockout or tagout device application. (i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.
(vii) Relocation of combustibles. Where practicable, all combustibles shall be relocated at least 35 feet (10.7 m) from the work site. Where relocation is impracticable, combustibles shall be protected with flameproofed covers or otherwise shielded with metal or asbestos guards or curtains.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.