OSHA SearchOSHA records by employer

Price Buster General Contracting: OSHA inspections and violations

Philadelphia, Pennsylvania · All Other Specialty Trade Contractors · NAICS 238990

1inspections
6citation items
$14,000current penalties
May 5, 2015last inspection

Price Buster General Contracting has one OSHA inspection on record in Pennsylvania.

OSHA opened it on May 5, 2015 on a referral, in Philadelphia.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $14,000 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Price Buster General Contracting averages $14,000 over 1 cited inspection in that time.

Price Buster General Contracting: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Price Buster General Contracting and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340779073 OPENED MAY 5, 2015Closed

Referral · Partial · Safety · 3 employees at the site · Closed Sep 30, 2022

933 N 5th Street, Philadelphia, PA 19123 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2)(i) · Scaffolds, general requirements
Serious$2,800$2,800Jul 24, 2015Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$2,800Jul 24, 2015Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$2,800$2,800Jul 24, 2015Final
Citation 1, item 3b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jul 24, 2015Final
Citation 1, item 4
29 CFR 1926.452(k)(1) · Rules for each type of scaffold
Serious$2,800$2,800Jul 24, 2015Final
Citation 1, item 5
29 CFR 1926.452(k)(4) · Rules for each type of scaffold
Serious$2,800$2,800Jul 24, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)(i)

(i) Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold shall be at least 12 inches (30 cm) wide. There is no minimum width requirement for boatswains' chairs.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

Other all other specialty trade contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.