OSHA SearchOSHA records by employer

Pridgeon & Clay Inc: OSHA inspections and violations

Grand Rapids, Michigan · Motor Vehicle Metal Stamping · NAICS 336370

19inspections
199citation items
$99,460current penalties
Oct 21, 2026last inspection

OSHA has inspected Pridgeon & Clay Inc 19 times in Michigan since 1989.

The latest one began on Oct 21, 2026 after a complaint, in Grand Rapids.

Those inspections ended with 199 citation items: 94 serious, 10 repeat and 95 other-than-serious.

Penalties were first proposed at $188,290 and now stand at $99,460, 47% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 15 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Pridgeon & Clay Inc averages $5,175 (2 cited inspections).

Pridgeon & Clay Inc also files yearly injury logs with OSHA, summarized below.

Pridgeon & Clay Inc: OSHA citation items per year, 1989 to 2026
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

653employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Pridgeon & Clay Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349237305 OPENED OCT 21, 2026Closed

Complaint · Partial · Safety · 480 employees at the site · Closed Oct 27, 2026

50 Cottage Grove St Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 349174672 OPENED SEP 17, 2026Open

Complaint · Partial · Health · 450 employees at the site · Open

50 Cottage Grove St Sw, Grand Rapids, MI 49507 · Metal Crown, Closure, and Other Metal Stamping (except Automotive) · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348812306 OPENED MAR 17, 2026Closed

Planned · Partial · Safety · 480 employees at the site · Closed Apr 20, 2026

50 Cottage Grove St Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.10034(12)
Serious$6,300$6,300Mar 26, 2026Final
Citation 1, item 1b
29 CFR 408.10011
Serious$0$0Mar 26, 2026Final
Citation 2, item 1
29 CFR 408.22132(1)
Other-than-serious$900$900Mar 26, 2026Final

Inspection 344453022 OPENED NOV 19, 2019Closed

Complaint · Partial · Safety · 500 employees at the site · Closed Apr 7, 2020

50 Cottage Grove St Sw, Grand Rapids, MI 49507 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.11872(2)
Serious$6,300$3,150Mar 5, 2020Final

Inspection 315375147 OPENED APR 9, 2014Closed

Complaint · Partial · Health · 753 employees at the site · Closed Aug 29, 2014

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$1,200$600Jun 23, 2014Closed
Citation 1, item 1b
29 CFR 1910.1026(l)(2)(i) · Hexavalent chromium
Serious$0$0Jun 23, 2014Closed

Inspection 315397711 OPENED JUL 3, 2013Closed

Complaint · Partial · Safety · 790 employees at the site · Closed Nov 25, 2013

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,450$1,225Sep 25, 2013Closed
Citation 2, item 1 Other-than-serious$0$0Sep 25, 2013Closed

Inspection 315403022 OPENED JUL 3, 2013Closed

Planned · Complete · Safety · 790 employees at the site · Closed Nov 25, 2013

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,450$1,225Sep 25, 2013Closed
Citation 1, item 2 Serious$2,450$1,225Sep 25, 2013Closed
Citation 1, item 3 Serious$1,400$560Sep 25, 2013Closed
Citation 1, item 4 Serious$1,400$560Sep 25, 2013Closed
Citation 1, item 5 Serious$4,500$2,250Sep 25, 2013Closed
Citation 1, item 6 Serious$4,500$2,250Sep 25, 2013Closed
Citation 1, item 7a Serious$4,500$2,250Sep 25, 2013Closed
Citation 1, item 7b Serious$0$0Sep 25, 2013Closed
Citation 1, item 8 Serious$2,450$980Sep 25, 2013Closed
Citation 1, item 9
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,450$1,225Sep 25, 2013Closed
Citation 1, item 10
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$2,450$1,225Sep 25, 2013Closed
Citation 1, item 11a
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$2,450$1,225Sep 25, 2013Closed
Citation 1, item 11b
29 CFR 1910.147(c)(7)(ib) · Lockout/tagout
Serious$0$0Sep 25, 2013Closed
Citation 2, item 1 Other-than-serious$0$0Sep 25, 2013Closed
Citation 2, item 2 Other-than-serious$0$0Sep 25, 2013Closed
Citation 2, item 3 Other-than-serious$0$0Sep 25, 2013Closed
Citation 2, item 4 Other-than-serious$0$0Sep 25, 2013Closed
Citation 2, item 5
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Sep 25, 2013Closed

Inspection 312036817 OPENED MAR 31, 2010Closed

Planned · Complete · Safety · 452 employees at the site · Closed Jul 2, 2010

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,200$600Jun 4, 2010Closed
Citation 1, item 2 Serious$1,200$600Jun 4, 2010Closed
Citation 1, item 3 Serious$1,200$600Jun 4, 2010Closed
Citation 1, item 4a Serious$1,200$600Jun 4, 2010Closed
Citation 1, item 4b Serious$0$0Jun 4, 2010Closed
Citation 1, item 5 Serious$1,200$600Jun 4, 2010Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,200$600Jun 4, 2010Closed
Citation 2, item 1 Repeat$6,000$3,000Jun 4, 2010Closed
Citation 2, item 2 Repeat$6,000$3,000Jun 4, 2010Closed
Citation 2, item 3 Repeat$6,000$3,000Jun 4, 2010Closed
Citation 2, item 4 Repeat$8,000$4,000Jun 4, 2010Closed
Citation 2, item 5 Repeat$6,000$3,000Jun 4, 2010Closed
Citation 2, item 6 Repeat$8,000$4,000Jun 4, 2010Closed
Citation 2, item 7
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Repeat$6,000$3,000Jun 4, 2010Closed
Citation 3, item 1 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 2 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 3 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 4a Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 4b Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 5 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 6 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 7 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 8 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 9 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 10
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 11
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 12
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 13
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 14
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 15
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 16 Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 17
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 18
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 19
29 CFR 1910.169(b)(3)(i) · Air receivers
Other-than-serious$0$0Jun 4, 2010Closed
Citation 3, item 20 Other-than-serious$0$0Jun 4, 2010Closed
Citation 4, item 1 Repeat$320$160Jun 4, 2010Closed
Citation 4, item 2 Repeat$320$160Jun 4, 2010Closed
Citation 4, item 3
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Repeat$320$160Jun 4, 2010Closed
11 older inspections

Inspection 308809755 OPENED JUL 15, 2008Closed

Planned · Complete · Safety · 627 employees at the site · Closed Jan 9, 2009

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 2 Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 3 Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 4 Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 5 Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 6 Serious$1,600$800Sep 30, 2008Closed
Citation 1, item 7 Serious$1,600$800Sep 30, 2008Closed
Citation 1, item 8a Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 8b Serious$0$0Sep 30, 2008Closed
Citation 1, item 9 Serious$1,600$800Sep 30, 2008Closed
Citation 1, item 10a Serious$1,600$800Sep 30, 2008Closed
Citation 1, item 10b Serious$0$0Sep 30, 2008Closed
Citation 1, item 11 Serious$1,200$600Sep 30, 2008Closed
Citation 1, item 12
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,600$800Sep 30, 2008Closed
Citation 1, item 13
29 CFR 1910.146(k)(2)(iv) · Permit-required confined spaces
Serious$1,200$600Sep 30, 2008Closed
Citation 2, item 1 Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 2a Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 3b Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 4 Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 5a Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 5b Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 6 Other-than-serious$0$0Sep 30, 2008Closed
Citation 2, item 7
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Sep 30, 2008Closed

Inspection 308797083 OPENED JUL 11, 2006Closed

Complaint · Partial · Safety · 603 employees at the site · Closed Aug 30, 2006

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,050$1,050Aug 2, 2006Closed

Inspection 307753962 OPENED APR 8, 2005Closed

Unprogrammed other · Partial · Safety · 639 employees at the site · Closed Feb 13, 2006

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,750$1,750May 10, 2005Final
Citation 1, item 2 Serious$1,050$1,050May 10, 2005Final

Inspection 304868391 OPENED FEB 12, 2004Closed

Complaint · Partial · Safety · 724 employees at the site · Closed Jun 24, 2004

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,125$562May 5, 2004Closed

Inspection 304868409 OPENED FEB 12, 2004Closed

Planned · Complete · Safety · 724 employees at the site · Closed Jun 24, 2004

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,125$562May 5, 2004Closed
Citation 1, item 2 Serious$1,125$562May 5, 2004Closed
Citation 1, item 3 Serious$1,125$562May 5, 2004Closed
Citation 1, item 4 Serious$1,125$562May 5, 2004Closed
Citation 1, item 5 Serious$1,125$562May 5, 2004Closed
Citation 1, item 6 Serious$1,125$562May 5, 2004Closed
Citation 1, item 7 Serious$1,125$562May 5, 2004Closed
Citation 1, item 8 Serious$1,125$562May 5, 2004Closed
Citation 2, item 1 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 2 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 3 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 4 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 5 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 6 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 7 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 8
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 9
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 10
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 11 Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 12
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0May 5, 2004Closed
Citation 2, item 13
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0May 5, 2004Closed

Inspection 304869027 OPENED SEP 15, 2003Closed

Complaint · Partial · Safety · 676 employees at the site · Closed Nov 21, 2003

50 Cottage Grove Sw, Grand Rapids, MI 49507 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Oct 14, 2003Closed

Inspection 127124147 OPENED AUG 27, 2001Closed

Complaint · Partial · Safety · 721 employees at the site · Closed Nov 7, 2001

50 Cottage Grove Sw, Grand Rapids, MI 49507 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,275$638Oct 5, 2001Closed

Inspection 127123768 OPENED JUN 4, 2001Closed

Planned · Complete · Safety · 721 employees at the site · Closed Oct 9, 2001

50 Cottage Grove Sw, Grand Rapids, MI 49507 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,500$750Jul 31, 2001Closed
Citation 1, item 2 Serious$1,500$750Jul 31, 2001Closed
Citation 1, item 3 Serious$1,500$750Jul 31, 2001Closed
Citation 1, item 4 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 5 Serious$1,500$750Jul 31, 2001Closed
Citation 1, item 6 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 7 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 8 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 9 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 10 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 11 Serious$1,500$750Jul 31, 2001Closed
Citation 1, item 12 Serious$2,625$1,312Jul 31, 2001Closed
Citation 1, item 13 Serious$1,875$938Jul 31, 2001Closed
Citation 1, item 14 Serious$1,875$938Jul 31, 2001Closed
Citation 1, item 15 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 16 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 17 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 18 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 19 Serious$1,125$562Jul 31, 2001Closed
Citation 1, item 20 Serious$1,500$750Jul 31, 2001Closed
Citation 1, item 21
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,500$750Jul 31, 2001Closed
Citation 2, item 1 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 2 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 3 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 4 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 5 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 6 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 7 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 8 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 9 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 10
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 11 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 12 Other-than-serious$0$0Jul 31, 2001Closed
Citation 2, item 13
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Jul 31, 2001Closed

Inspection 127115145 OPENED OCT 20, 1997Closed

Planned · Complete · Safety · 800 employees at the site · Closed Feb 19, 1998

50 Cottage Grove Sw, Grand Rapids, MI 49507 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,125$562Dec 22, 1997Closed
Citation 1, item 2 Serious$1,125$562Dec 22, 1997Closed
Citation 1, item 3 Serious$1,125$562Dec 22, 1997Closed
Citation 1, item 4 Serious$1,125$562Dec 22, 1997Closed
Citation 1, item 5 Serious$1,125$562Dec 22, 1997Closed
Citation 1, item 6 Serious$1,125$562Dec 22, 1997Closed
Citation 1, item 7
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,875$938Dec 22, 1997Closed
Citation 1, item 8
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$1,125$562Dec 22, 1997Closed
Citation 2, item 1 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 2 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 3 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 4 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 5 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 6 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 7 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 8 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 9 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 10 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 11
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 12
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 13 Other-than-serious$0$0Dec 22, 1997Closed
Citation 2, item 14
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Dec 22, 1997Closed

Inspection 124828096 OPENED SEP 13, 1994Closed

Planned · Complete · Safety · 450 employees at the site · Closed Mar 15, 1995

50 Cottage Grove Sw, Grand Rapids, MI 49507 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,125$562Dec 2, 1994Closed
Citation 1, item 2 Serious$1,125$562Dec 2, 1994Closed
Citation 1, item 3 Serious$1,125$562Dec 2, 1994Closed
Citation 1, item 4 Serious$1,125$562Dec 2, 1994Closed
Citation 1, item 5 Serious$1,500$750Dec 2, 1994Closed
Citation 1, item 6 Serious$1,500$750Dec 2, 1994Closed
Citation 1, item 7 Serious$1,500$750Dec 2, 1994Closed
Citation 1, item 8 Serious$1,500$750Dec 2, 1994Closed
Citation 1, item 9
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,500$750Dec 2, 1994Closed
Citation 1, item 10
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$1,500$750Dec 2, 1994Closed
Citation 2, item 1 Other-than-serious$0$0Dec 2, 1994Closed
Citation 2, item 2 Other-than-serious$0$0Dec 2, 1994Closed
Citation 2, item 3 Other-than-serious$0$0Dec 2, 1994Closed
Citation 2, item 4 Other-than-serious$0$0Dec 2, 1994Closed
Citation 2, item 5 Other-than-serious$0$0Dec 2, 1994Closed
Citation 2, item 6
29 CFR 1910.304(f)(5)(vc)(1) · Grounding and circuit protection
Other-than-serious$0$0Dec 2, 1994Closed

Inspection 110692365 OPENED NOV 22, 1989Closed

Planned · Complete · Safety · 300 employees at the site · Closed Jan 23, 1990

50 Cottage Grove Sw, Grand Rapids, MI 49507 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$630$630Dec 20, 1989Closed
Citation 2, item 1 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 2 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 3 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 4 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 5 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 6 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 7 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 8 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 9 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 10
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 11 Other-than-serious$0$0Dec 20, 1989Closed
Citation 2, item 12 Other-than-serious$0$0Dec 20, 1989Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Grand Rapids site logged 15 recordable injuries or illnesses among about 529 workers: 2.9 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 204 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Pridgeon & Clay - 50 Cottage Grove
Grand Rapids · 2025
529 1512.92.7
Pridgeon & Clay - 1111 Wallen
Grand Rapids · 2025
66 304.72.7
Pridgeon & Clay - 158 Cottage Grove
Grand Rapids · 2025
58 417.12.7
Pridgeon and Clay
Grand Rapids · 2023
535 3835.42.7
Pridgeon and Clay- Advanced Engineering Center
Grand Rapids · 2021
61 101.52.7
Pridgeon and Clay - 50 CG
Grand Rapids · 2020
481 1463.22.7
Pridgeon & Clay, Inc. R&D Center
Grand Rapids · 2020
81 334.02.7
Pridgeon & Clay, Inc. USDC
Grand Rapids · 2020
56 000.02.7

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1026(l)(2)(i)

(2) Employee information and training. (i) The employer shall ensure that each employee can demonstrate knowledge of at least the following:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.169 · Air receivers

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.309

29 CFR 3090.300

29 CFR 3254.7201

29 CFR 4080.1011

29 CFR 4081.11

29 CFR 4081.1115

29 CFR 4081.1211

29 CFR 4081.1212

29 CFR 4081.1222

29 CFR 4081.1223

29 CFR 4081.125

29 CFR 4081.1254

29 CFR 4081.1281

29 CFR 4081.1421

29 CFR 4081.1442

29 CFR 4081.15

29 CFR 4081.1824

29 CFR 4081.1852

29 CFR 4081.1865

29 CFR 4081.187

29 CFR 4081.213

29 CFR 4081.215

29 CFR 4081.2154

29 CFR 4081.2161

29 CFR 4081.2164

29 CFR 4081.217

29 CFR 4081.2176

29 CFR 4081.220

29 CFR 4081.231

29 CFR 4081.2411

29 CFR 4081.2412

29 CFR 4081.2442

29 CFR 4081.2445

29 CFR 4081.2461

29 CFR 4081.2462

29 CFR 4081.2463

29 CFR 4081.2471

29 CFR 4081.2473

29 CFR 4081.2476

29 CFR 4081.2477

29 CFR 4081.2616

29 CFR 4081.2622

29 CFR 4081.2635

29 CFR 4081.2637

29 CFR 4081.2646

29 CFR 4081.2648

29 CFR 4081.33

29 CFR 4081.3312

29 CFR 4081.34

29 CFR 4081.355

29 CFR 4081.36

29 CFR 4081.3835

29 CFR 4081.3838

29 CFR 4081.4005

29 CFR 4081.4007

29 CFR 4081.442

29 CFR 4081.443

29 CFR 4081.446

29 CFR 4081.447

29 CFR 4081.4934

29 CFR 4081.5832

29 CFR 4081.632

29 CFR 4081.645

29 CFR 4081.651

29 CFR 4081.685

29 CFR 4081.711

29 CFR 4081.716

29 CFR 4081.722

29 CFR 4081.727

29 CFR 4081.731

29 CFR 4081.736

29 CFR 4081.835

29 CFR 4082.2129

Other motor vehicle metal stamping employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.